1 SSC2 2 0x1 3 Read warning 4 Warning 5 The tape drive is having problems reading data. No data has been\ 6 lost, but there has been a reduction in the performance of the\ 7 tape. 8 The drive is having severe trouble reading. 9 10 SSC2 11 0x2 12 Write warning 13 Warning 14 The tape drive is having problems writing data. No data has been\ 15 lost, but there has been a reduction in the capacity of the tape. 16 The drive is having severe trouble writing. 17 18 SSC2 19 0x3 20 Hard error 21 Warning 22 The operation has stopped because an error has occurred while\ 23 reading or writing data that the drive cannot correct. 24 The drive had a hard read or write error. 25 26 SSC2 27 0x4 28 Media 29 Critical 30 Your data is at risk:\ 31 1. Copy any data you require from this tape.\ 32 2. Do not use this tape again.\ 33 3. Restart the operation with a different tape. 34 Media can no longer be written/read, or performance\ 35 is severely degraded. 36 37 SSC2 38 0x5 39 Read failure 40 Critical 41 The tape is damaged or the drive is faulty. Call the tape drive\ 42 supplier help line. 43 The drive can no longer read data from the tape. 44 45 SSC2 46 0x6 47 Write failure 48 Critical 49 The tape is from a faulty batch or the tape drive is faulty:\ 50 1. Use a good tape to test the drive.\ 51 2. If the problem persists, call the tape drive supplier help line. 52 The drive can no longer write data to the tape. 53 54 SSC2 55 0x7 56 Media life 57 Warning 58 The tape cartridge has reached the end of its calculated useful\ 59 life:\ 60 1. Copy any data you need to another tape.\ 61 2. Discard the old tape. 62 The media has exceeded its specified life. 63 64 SSC2 65 0x8 66 Not data grade 67 Warning 68 The cartridge is not data-grade. Any data you write to the tape\ 69 is at risk. Replace the cartridge with a data-grade tape. 70 The drive has not been able to read the MRS (Media Recognition\ 71 System) stripes. MRS stripes are pre-defined stripes at BOM to\ 72 identify the media. Media may be audio/video grade and is not for\ 73 a data streaming device. 74 75 SSC2 76 0x9 77 Write protect 78 Critical 79 You are trying to write to a write protected cartridge. Remove\ 80 the write protection or use another tape. 81 Write command attempted a write to a write protected tape. 82 83 SSC2 84 0xa 85 No removal 86 Information 87 You cannot eject the cartridge because the tape drive is in use.\ 88 Wait until the operation is complete before ejecting the cartridge. 89 Manual or software unload attempted when prevent media removal\ 90 is on. 91 92 SSC2 93 0xb 94 Cleaning media 95 Information 96 The tape in the drive is a cleaning cartridge. 97 Cleaning tape loaded into drive. 98 99 SSC2 100 0xc 101 Unsupported format 102 Information 103 You have tried to load a cartridge of a type that is not supported\ 104 by this drive. 105 Attempted load of unsupported tape format (e.g., DDS2 in DDS1\ 106 drive). 107 108 SSC2 109 0xd 110 Recoverable snapped tape 111 Critical 112 The operation has failed because the tape in the drive has\ 113 snapped:\ 114 1. Discard the old tape.\ 115 2. Restart the operation with a different tape. 116 Tape snapped/cut in the drive where media can be ejected. 117 118 SSC2 119 0xe 120 Unrecoverable snapped tape 121 Critical 122 The operation has failed because the tape in the drive has\ 123 snapped:\ 124 1. Do not attempt to extract the tape cartridge.\ 125 2. Call the tape drive supplier help line. 126 Tape snapped/cut in the drive where media cannot be ejected. 127 128 SSC2 129 0xf 130 Memory chip in cartridge failure 131 Warning 132 The memory in the tape cartridge has failed, which reduces\ 133 performance. Do not use the cartridge for further write operations. 134 Memory chip failed in cartridge. 135 136 SSC2 137 0x10 138 Forced eject 139 Critical 140 The operation has failed because the tape cartridge was manually\ 141 de-mounted while the tape drive was actively writing or reading. 142 Manual or forced eject while drive actively writing or reading. 143 144 SSC2 145 0x11 146 Read only format 147 Warning 148 You have loaded a cartridge of a type that is read-only in this\ 149 drive. The cartridge will appear as write protected. 150 Media loaded that is read-only format. 151 152 SSC2 153 0x12 154 Tape directory corrupted on load 155 Warning 156 The tape directory on the tape cartridge has been corrupted. File\ 157 search performance will be degraded. The tape directory can be\ 158 rebuilt by reading all the data on the cartridge. 159 Tape drive powered down with tape loaded, or permanent error\ 160 prevented the tape directory being updated. 161 162 SSC2 163 0x13 164 Nearing media life 165 Information 166 The tape cartridge is nearing the end of its calculated life.\ 167 It is recommended that you:\ 168 1. Use another tape cartridge for your next backup.\ 169 2. Store this tape cartridge in a safe place in case you need\ 170 to restore data from it. 171 Media may have exceeded its specified number of passes. 172 173 SSC2 174 0x14 175 Clean now 176 Critical 177 The tape drive needs cleaning:\ 178 1. If the operation has stopped, eject the tape and clean the\ 179 drive.\ 180 2. If the operation has not stopped, wait for it to finish and\ 181 then clean the drive.\ 182 Check the tape drive users manual for device specific cleaning\ 183 instructions. 184 The drive has a head clog or needs cleaning. 185 186 SSC2 187 0x15 188 Clean periodic 189 Warning 190 The tape drive is due for routine cleaning:\ 191 1. Wait for the current operation to finish.\ 192 2. Then use a cleaning cartridge.\ 193 Check the tape drive users manual for device specific cleaning\ 194 instructions. 195 The drive is ready for a periodic cleaning. 196 197 SSC2 198 0x16 199 Expired cleaning media 200 Critical 201 The last cleaning cartridge used in the tape drive has worn out:\ 202 1. Discard the worn out cleaning cartridge.\ 203 2. Wait for the current operation to finish.\ 204 3. Then use a new cleaning cartridge. 205 The cleaning tape has expired. 206 207 SSC2 208 0x17 209 Invalid cleaning tape 210 Critical 211 The last cleaning cartridge used in the tape drive was an invalid\ 212 type:\ 213 1. Do not use this cleaning cartridge in this drive.\ 214 2. Wait for the current operation to finish.\ 215 3. Then use a valid cleaning cartridge. 216 Invalid cleaning tape type used. 217 218 SSC2 219 0x18 220 Retension requested 221 Warning 222 The tape drive has requested a retension operation. 223 The drive is having severe trouble reading or writing, that will\ 224 be resolved by a retension cycle. 225 226 SSC2 227 0x19 228 Dual-port interface error 229 Warning 230 A redundant interface port on the tape drive has failed. 231 Failure of one interface port in a dual-port configuration (i.e.,\ 232 Fibre Channel) 233 234 SSC2 235 0x1a 236 Cooling fan failure 237 Warning 238 A tape drive cooling fan has failed. 239 Fan failure inside tape drive mechanism or tape drive enclosure. 240 241 SSC2 242 0x1b 243 Power supply failure 244 Warning 245 A redundant power supply has failed inside the tape drive\ 246 enclosure. Check the enclosure users manual for instructions on\ 247 replacing the failed power supply. 248 Redundant PSU failure inside the tape drive enclosure or rack\ 249 subsystem. 250 251 SSC2 252 0x1c 253 Power consumption 254 Warning 255 The tape drive power consumption is outside the specified range. 256 Power consumption of the tape drive is outside specified range. 257 258 SSC2 259 0x1d 260 Drive maintenance 261 Warning 262 Preventive maintenance of the tape drive is required. Check the\ 263 tape drive users manual for device specific preventive maintenance\ 264 tasks or call the tape drive supplier help line. 265 The drive requires preventive maintenance (not cleaning). 266 267 SSC2 268 0x1e 269 Hardware A 270 Critical 271 The tape drive has a hardware fault:\ 272 1. Eject the tape or magazine.\ 273 2. Reset the drive.\ 274 3. If the problem persists, call the tape drive supplier help line. 275 The drive has a hardware fault that requires reset to recover. 276 277 SSC2 278 0x1f 279 Hardware B 280 Critical 281 The tape drive has a hardware fault:\ 282 1. Turn the tape drive off and then on again.\ 283 2. Restart the operation.\ 284 3. If the problem persists, call the tape drive supplier help line. 285 The drive has a hardware fault that is not read/write related or\ 286 requires a power cycle to recover. 287 288 SSC2 289 0x20 290 Interface 291 Warning 292 The tape drive has a problem with the application client\ 293 interface:\ 294 1. Check the cables and cable connections.\ 295 2. Restart the operation. 296 The drive has identified an interface fault. 297 298 SSC2 299 0x21 300 Eject media 301 Critical 302 The operation has failed:\ 303 1. Eject the tape or magazine.\ 304 2. Insert the tape or magazine again.\ 305 3. Restart the operation. 306 Failed to finish mounting. 307 308 SSC2 309 0x22 310 Download fail 311 Warning 312 The firmware download has failed because you have tried to use\ 313 the incorrect firmware for this tape drive. Obtain the correct\ 314 firmware and try again. 315 Firmware download failed. 316 317 SSC2 318 0x23 319 Drive humidity 320 Warning 321 Environmental conditions inside the tape drive are outside the\ 322 specified humidity range. 323 Drive humidity limits exceeded. 324 325 SSC2 326 0x24 327 Drive temperature 328 Warning 329 Environmental conditions inside the tape drive are outside the\ 330 specified temperature range. 331 Drive temperature limits exceeded. 332 333 SSC2 334 0x25 335 Drive voltage 336 Warning 337 The voltage supply to the tape drive is outside the specified\ 338 range. 339 Drive voltage limits exceeded. 340 341 SSC2 342 0x26 343 Predictive failure 344 Critical 345 A hardware failure of the tape drive is predicted. Call the tape\ 346 drive supplier help line. 347 Predictive failure of drive hardware. 348 349 SSC2 350 0x27 351 Diagnostics required 352 Warning 353 The tape drive may have a hardware fault. Run extended diagnostics\ 354 to verify and diagnose the problem. Check the tape drive users\ 355 manual for device specific instructions on running extended\ 356 diagnostics tests. 357 The drive may have a hardware fault that may be identified by\ 358 extended diagnostics (i.e. SEND DIAGNOSTIC command). 359 360 SSC2 361 0x28 362 Loader hardware A 363 Critical 364 The changer mechanism is having difficulty communicating with the\ 365 tape drive:\ 366 1. Turn the autoloader off then on.\ 367 2. Restart the operation.\ 368 3. If a problem persists, call the tape drive supplier help line. 369 Loader mechanism is having trouble communicating with the tape\ 370 drive. 371 372 SSC2 373 0x29 374 Loader stray tape 375 Critical 376 A tape has been left in the autoloader by a previous hardware\ 377 fault:\ 378 1. Insert an empty magazine to clear the fault.\ 379 2. If the fault does not clear, turn the autoloader off and then\ 380 on again.\ 381 3. If the problem persists, call the tape drive supplier help line. 382 Stray tape left in loader after previous error recovery. 383 384 SSC2 385 0x2a 386 Loader hardware B 387 Warning 388 There is a problem with the autoloader mechanism. 389 Loader mechanism has a hardware fault. 390 391 SSC2 392 0x2b 393 Loader door 394 Critical 395 The operation has failed because the autoloader door is open:\ 396 1. Clear any obstructions from the autoloader door.\ 397 2. Eject the magazine and then insert it again.\ 398 3. If the fault does not clear, turn the autoloader off and then\ 399 on again.\ 400 4. If the problem persists, call the tape drive supplier help line. 401 Tape changer door open. 402 403 SSC2 404 0x2c 405 Loader hardware C 406 Critical 407 The autoloader has a hardware fault:\ 408 1. Turn the autoloader off and then on again.\ 409 2. Restart the operation.\ 410 3. If the problem persists, call the tape drive supplier help\ 411 line.\ 412 Check the autoloader users manual for device specific instructions\ 413 on turning the device power on and off. 414 The loader mechanism has a hardware fault that is not mechanically related. 415 416 SSC2 417 0x2d 418 Loader magazine 419 Critical 420 The autoloader cannot operate without the magazine:\ 421 1. Insert the magazine into the autoloader.\ 422 2. Restart the operation. 423 Loader magazine not present. 424 425 SSC2 426 0x2e 427 Loader predictive failure 428 Warning 429 A hardware failure of the changer mechanism is predicted. Call\ 430 the tape drive supplier help line. 431 Predictive failure of loader mechanism hardware. 432 433 SSC2 434 0x2f 435 Reserved 436 Reserved 437 "" 438 "" 439 440 SSC2 441 0x30 442 Reserved 443 Reserved 444 "" 445 "" 446 447 SSC2 448 0x31 449 Reserved 450 Reserved 451 "" 452 "" 453 454 SSC2 455 0x32 456 Lost statistics 457 Warning 458 Media statistics have been lost at some time in the past. 459 Drive or library powered down with tape loaded. 460 461 SSC2 462 0x33 463 Tape directory invalid at unload 464 Warning 465 The tape directory on the tape cartridge just unloaded has been\ 466 corrupted. File search performance will be degraded. The tape\ 467 directory can be rebuilt by reading all the data. 468 Error preventing the tape directory being updated on unload. 469 470 SSC2 471 0x34 472 Tape system area write failure 473 Critical 474 The tape just unloaded could not write its system area\ 475 successfully:\ 476 1. Copy data to another tape cartridge.\ 477 2. Discard the old cartridge. 478 Write errors while writing the system area on unload. 479 480 SSC2 481 0x35 482 Tape system area read failure 483 Critical 484 The tape system area could not be read successfully at load time:\ 485 1. Copy data to another tape cartridge. 486 Read errors while reading the system area on load. 487 488 SSC2 489 0x36 490 No start of data 491 Critical 492 The start of data could not be found on the tape:\ 493 1. Check that you are using the correct format tape.\ 494 2. Discard the tape or return the tape to your supplier. 495 Tape damaged, bulk erased, or incorrect format. 496 497 SSC2 498 0x37 499 Loading failure 500 Critical 501 The operation has failed because the media cannot be loaded and\ 502 threaded.\ 503 1. Remove the cartridge, inspect it as specified in the product\ 504 manual, and retry the operation.\ 505 2. If the problem persists, call the tape drive supplier help line. 506 The drive is unable to load the media and thread the tape. 507 508 SSC3 509 0x38 510 Unrecoverable unload failure 511 Critical 512 The operation has failed because the medium cannot be unloaded:\ 513 1. Do not attempt to extract the tape cartridge.\ 514 2. Call the tape driver supplier help line. 515 The drive is unable to unload the medium. 516 517 SSC2 518 0x38 519 Reserved 520 Reserved 521 "" 522 "" 523 524 SSC3 525 0x39 526 Automation interface failure 527 Critical 528 The tape drive has a problem with the automation interface:\ 529 1. Check the power to the automation system.\ 530 2. Check the cables and cable connections.\ 531 3. Call the supplier help line if problem persists. 532 The drive has identified an interface fault. 533 534 SSC2 535 0x39 536 Reserved 537 Reserved 538 "" 539 "" 540 541 SSC3 542 0x3a 543 Firmware failure 544 Warning 545 The tape drive has reset itself due to a detected firmware fault. If\ 546 problem persists, call the supplier help line. 547 Firmware bug. 548 549 SSC2 550 0x3a 551 Reserved 552 Reserved 553 "" 554 "" 555 556 SSC3 557 0x3b 558 WORM medium integrity check failed 559 Warning 560 The tape drive has detected an inconsistency during the WORM medium\ 561 integrity checks. Someone may have tampered with the cartridge. 562 Someone has tampered with the WORM medium. 563 564 SSC2 565 0x3b 566 Reserved 567 Reserved 568 "" 569 "" 570 571 SSC3 572 0x3c 573 WORM medium overwrite attempted 574 Warning 575 An attempt had been made to overwrite user data on a WORM medium:\ 576 1. If a WORM medium was used inadvertently, replace it with a\ 577 normal data medium.\ 578 2. If a WORM medium was used intentionally:\ 579 a) check that the software application is compatible with the\ 580 WORM medium format you are using.\ 581 b) check that the medium is bar-coded correctly for WORM. 582 The application software does not recognize the medium as WORM. 583 584 SSC2 585 0x3c 586 Reserved 587 Reserved 588 "" 589 "" 590 591 SSC2 592 0x3d 593 Reserved 594 Reserved 595 "" 596 "" 597 598 SSC2 599 0x3e 600 Reserved 601 Reserved 602 "" 603 "" 604 605 SSC2 606 0x3f 607 Reserved 608 Reserved 609 "" 610 "" 611 612 SSC2 613 0x40 614 Reserved 615 Reserved 616 "" 617 "" 618 619 SMC2 620 0x1 621 Library hardware A 622 Critical 623 The library mechanism is having difficulty communicating with\ 624 the drive:\ 625 1. Turn the library off then on.\ 626 2. Restart the operation.\ 627 3. If the problem persists, call the library supplier help line. 628 Changer mechanism is having trouble communicating with the\ 629 internal drive. 630 631 SMC2 632 0x2 633 Library hardware B 634 Warning 635 There is a problem with the library mechanism. If problem\ 636 persists, call the library supplier help line. 637 Changer mechanism has a hardware fault. 638 639 SMC2 640 0x3 641 Library hardware C 642 Critical 643 The library has a hardware fault:\ 644 1. Reset the library.\ 645 2. Restart the operation.\ 646 Check the library users manual for device specific instructions\ 647 on resetting the device. 648 The changer mechanism has a hardware fault that requires a reset\ 649 to recover. 650 651 SMC2 652 0x4 653 Library hardware D 654 Critical 655 The library has a hardware fault:\ 656 1. Turn the library off then on again.\ 657 2. Restart the operation.\ 658 3. If the problem persists, call the library supplier help line.\ 659 Check the library users manual for device specific instructions\ 660 on turning the device power on and off. 661 The changer mechanism has a hardware fault that is not\ 662 mechanically related or requires a power cycle to recover. 663 664 SMC2 665 0x5 666 Library diagnostics required 667 Warning 668 The library mechanism may have a hardware fault. Run extended\ 669 diagnostics to verify and diagnose the problem. Check the library\ 670 users manual for device specific instructions on running extended\ 671 diagnostics test. 672 The changer mechanism may have a hardware fault which would be\ 673 identified by extended diagnostics. 674 675 SMC2 676 0x6 677 Library interface 678 Critical 679 The library has a problem with the host interface:\ 680 1. Check the cables and connections.\ 681 2. Restart the operation. 682 The library has identified an interface fault. 683 684 SMC2 685 0x7 686 Predictive failure 687 Warning 688 A hardware failure of the library is predicted. Call the library\ 689 supplier help line. 690 Predictive failure of library hardware. 691 692 SMC2 693 0x8 694 Library maintenance 695 Warning 696 Preventive maintenance of the library is required. Check the\ 697 library users manual for device specific preventative maintenance\ 698 tasks, or call your library supplier help line. 699 Library preventative maintenance required. 700 701 SMC2 702 0x9 703 Library humidity limits 704 Critical 705 General environmental conditions inside the library are outside\ 706 the specified humidity range. 707 Library humidity limits exceeded. 708 709 SMC2 710 0xa 711 Library temperature limits 712 Critical 713 General environmental conditions inside the library are outside\ 714 the specified temperature range. 715 Library temperature limits exceeded. 716 717 SMC2 718 0xb 719 Library voltage limits 720 Critical 721 The voltage supply to the library is outside the specified range.\ 722 There is a potential problem with the power supply or failure of\ 723 a redundant power supply. 724 Library voltage limits exceeded. 725 726 SMC2 727 0xc 728 Library stray tape 729 Critical 730 A cartridge has been left inside the library by a previous\ 731 hardware fault:\ 732 1. Insert an empty magazine to clear the fault.\ 733 2. If the fault does not clear, turn the library off and then\ 734 on again.\ 735 3. If the problem persists, call the library supplier help line. 736 Stray cartridge left in library after previous error recovery. 737 738 SMC2 739 0xd 740 Library pick retry 741 Warning 742 There is a potential problem with the drive ejecting cartridges\ 743 or with the library mechanism picking a cartridge from a slot.\ 744 1. No action needs to be taken at this time.\ 745 2. If the problem persists, call the library supplier help line. 746 Operation to pick a cartridge from a slot had to perform an\ 747 excessive number of retries before succeeding. 748 749 SMC2 750 0xe 751 Library place retry 752 Warning 753 There is a potential problem with the library mechanism placing\ 754 a cartridge into a slot.\ 755 1. No action needs to be taken at this time.\ 756 2. If the problem persists, call the library supplier help line. 757 Operation to place a cartridge in a slot had to perform an\ 758 excessive number of retries before succeeding. 759 760 SMC2 761 0xf 762 Library load retry 763 Warning 764 There is a potential problem with the drive or the library\ 765 mechanism loading cartridges, or an incompatible cartridge. 766 Operation to load a cartridge in a drive had to perform an\ 767 excessive number of retries before succeeding. 768 769 SMC2 770 0x10 771 Library door 772 Critical 773 The library has failed because the door is open:\ 774 1. Clear any obstructions from the library door.\ 775 2. Close the library door.\ 776 3. If the problem persists, call the library supplier help line. 777 Changer door open prevents library functioning. 778 779 SMC2 780 0x11 781 Library mail-slot 782 Critical 783 There is a mechanical problem with the library media import/export\ 784 mail-slot. 785 Mechanical problem with import/export mail-slot. 786 787 SMC2 788 0x12 789 Library magazine 790 Critical 791 The library can not operate without the magazine.\ 792 1. Insert the magazine into the library.\ 793 2. Restart the operation. 794 Library magazine not present. 795 796 SMC2 797 0x13 798 Library security 799 Warning 800 Library security has been compromised. 801 Library door opened then closed during operation. 802 803 SMC2 804 0x14 805 Library security mode 806 Information 807 The library security mode has been changed. The library has\ 808 either been put into secure mode, or the library has exited the\ 809 secure mode. This is for information purposes only. No action\ 810 is required. 811 Library security mode changed. 812 813 SMC2 814 0x15 815 Library off-line 816 Information 817 The library has been manually turned off-line and is unavailable\ 818 for use. 819 Library manually turned off-line. 820 821 SMC2 822 0x16 823 Library drive off-line 824 Information 825 A drive inside the library has been taken off-line. This is for\ 826 information purposes only. No action is required. 827 Library turned internal drive off-line. 828 829 SMC2 830 0x17 831 Library scan retry 832 Warning 833 There is a potential problem with the bar code label or the\ 834 scanner hardware in the library mechanism.\ 835 1. No action needs to be taken at this time.\ 836 2. If the problem persists, call the library supplier help line. 837 Operation to scan the bar code on a cartridge had to perform and\ 838 excessive number of retries before succeeding. 839 840 SMC2 841 0x18 842 Library inventory 843 Critical 844 The library has detected an inconsistency in its inventory.\ 845 1. Redo the library inventory to correct inconsistency.\ 846 2. Restart the operation.\ 847 Check the applications users manual or the hardware users manual\ 848 for specific instructions on redoing the library inventory. 849 Inconsistent media inventory. 850 851 SMC2 852 0x19 853 Library illegal operation 854 Warning 855 A library operation has been attempted that is invalid at this\ 856 time. 857 Illegal operation detected. 858 859 SMC2 860 0x1a 861 Dual-port interface error 862 Warning 863 A redundant interface port on the library has failed. 864 Failure of one interface port in a dual-port configuration. 865 866 SMC2 867 0x1b 868 Cooling fan failure 869 Warning 870 A library cooling fan has failed. 871 One or more fans inside the library have failed. Internal flag\ 872 state only cleared when all flags are working again. 873 874 SMC2 875 0x1c 876 Power supply 877 Warning 878 A redundant power supply has failed inside the library. Check the\ 879 library users manual for instructions on replacing the failed\ 880 power supply. 881 Redundant power supply failure inside the library subsystem. 882 883 SMC2 884 0x1d 885 Power consumption 886 Warning 887 The library power consumption is outside the specified range. 888 Power consumption of one or more devices inside the library is\ 889 outside the specified range. 890 891 SMC2 892 0x1e 893 Pass-through mechanism failure 894 Critical 895 A failure has occurred in the cartridge pass-through mechanism\ 896 between two library modules. 897 Error occurred in pass-through mechanism during self test or\ 898 while attempting to transfer a cartridge between library modules. 899 900 SMC2 901 0x1f 902 Cartridge in pass-through mechanism 903 Critical 904 A cartridge has been left in the pass-through mechanism from a\ 905 previous hardware fault. Check the library users guide for\ 906 instructions on clearing this fault. 907 Cartridge left in the pass-through mechanism between two library\ 908 modules. 909 910 SMC2 911 0x20 912 Unreadable bar code labels 913 Information 914 The library was unable to read the bar code on a cartridge. 915 Unable to read a bar code label on a cartridge during library\ 916 inventory/scan. 917 918 SMC2 919 0x21 920 Reserved 921 Reserved 922 "" 923 "" 924 925 SMC2 926 0x22 927 Reserved 928 Reserved 929 "" 930 "" 931 932 SMC2 933 0x23 934 Reserved 935 Reserved 936 "" 937 "" 938 939 SMC2 940 0x24 941 Reserved 942 Reserved 943 "" 944 "" 945 946 SMC2 947 0x25 948 Reserved 949 Reserved 950 "" 951 "" 952 953 SMC2 954 0x26 955 Reserved 956 Reserved 957 "" 958 "" 959 960 SMC2 961 0x27 962 Reserved 963 Reserved 964 "" 965 "" 966 967 SMC2 968 0x28 969 Reserved 970 Reserved 971 "" 972 "" 973 974 SMC2 975 0x29 976 Reserved 977 Reserved 978 "" 979 "" 980 981 SMC2 982 0x2a 983 Reserved 984 Reserved 985 "" 986 "" 987 988 SMC2 989 0x2b 990 Reserved 991 Reserved 992 "" 993 "" 994 995 SMC2 996 0x2c 997 Reserved 998 Reserved 999 "" 1000 "" 1001 1002 SMC2 1003 0x2d 1004 Reserved 1005 Reserved 1006 "" 1007 "" 1008 1009 SMC2 1010 0x2e 1011 Reserved 1012 Reserved 1013 "" 1014 "" 1015 1016 SMC2 1017 0x2f 1018 Reserved 1019 Reserved 1020 "" 1021 "" 1022 1023 SMC2 1024 0x30 1025 Reserved 1026 Reserved 1027 "" 1028 "" 1029 1030 SMC2 1031 0x31 1032 Reserved 1033 Reserved 1034 "" 1035 "" 1036 1037 SMC2 1038 0x32 1039 Reserved 1040 Reserved 1041 "" 1042 "" 1043 1044 SMC2 1045 0x33 1046 Reserved 1047 Reserved 1048 "" 1049 "" 1050 1051 SMC2 1052 0x34 1053 Reserved 1054 Reserved 1055 "" 1056 "" 1057 1058 SMC2 1059 0x35 1060 Reserved 1061 Reserved 1062 "" 1063 "" 1064 1065 SMC2 1066 0x36 1067 Reserved 1068 Reserved 1069 "" 1070 "" 1071 1072 SMC2 1073 0x37 1074 Reserved 1075 Reserved 1076 "" 1077 "" 1078 1079 SMC2 1080 0x38 1081 Reserved 1082 Reserved 1083 "" 1084 "" 1085 1086 SMC2 1087 0x38 1088 Reserved 1089 Reserved 1090 "" 1091 "" 1092 1093 SMC2 1094 0x39 1095 Reserved 1096 Reserved 1097 "" 1098 "" 1099 1100 SMC2 1101 0x3a 1102 Reserved 1103 Reserved 1104 "" 1105 "" 1106 1107 SMC2 1108 0x3b 1109 Reserved 1110 Reserved 1111 "" 1112 "" 1113 1114 SMC2 1115 0x3c 1116 Reserved 1117 Reserved 1118 "" 1119 "" 1120 1121 SMC2 1122 0x3d 1123 Reserved 1124 Reserved 1125 "" 1126 "" 1127 1128 SMC2 1129 0x3e 1130 Reserved 1131 Reserved 1132 "" 1133 "" 1134 1135 SMC2 1136 0x3f 1137 Reserved 1138 Reserved 1139 "" 1140 "" 1141 1142 SMC2 1143 0x40 1144 Reserved 1145 Reserved 1146 "" 1147 "" 1148 1149
