      1 SSC2
      2 0x1
      3 Read warning
      4 Warning
      5 The tape drive is having problems reading data. No data has been\
      6 lost, but there has been a reduction in the performance of the\
      7 tape.
      8 The drive is having severe trouble reading.
      9 
     10 SSC2
     11 0x2
     12 Write warning
     13 Warning
     14 The tape drive is having problems writing data. No data has been\
     15 lost, but there has been a reduction in the capacity of the tape.
     16 The drive is having severe trouble writing.
     17 
     18 SSC2
     19 0x3
     20 Hard error
     21 Warning
     22 The operation has stopped because an error has occurred while\
     23 reading or writing data that the drive cannot correct.
     24 The drive had a hard read or write error.
     25 
     26 SSC2
     27 0x4
     28 Media
     29 Critical
     30 Your data is at risk:\
     31 1. Copy any data you require from this tape.\
     32 2. Do not use this tape again.\
     33 3. Restart the operation with a different tape.
     34 Media can no longer be written/read, or performance\
     35 is severely degraded.
     36 
     37 SSC2
     38 0x5
     39 Read failure
     40 Critical
     41 The tape is damaged or the drive is faulty. Call the tape drive\
     42 supplier help line.
     43 The drive can no longer read data from the tape.
     44 
     45 SSC2
     46 0x6
     47 Write failure
     48 Critical
     49 The tape is from a faulty batch or the tape drive is faulty:\
     50 1. Use a good tape to test the drive.\
     51 2. If the problem persists, call the tape drive supplier help line.
     52 The drive can no longer write data to the tape.
     53 
     54 SSC2
     55 0x7
     56 Media life
     57 Warning
     58 The tape cartridge has reached the end of its calculated useful\
     59 life:\
     60 1. Copy any data you need to another tape.\
     61 2. Discard the old tape.
     62 The media has exceeded its specified life.
     63 
     64 SSC2
     65 0x8
     66 Not data grade
     67 Warning
     68 The cartridge is not data-grade. Any data you write to the tape\
     69 is at risk. Replace the cartridge with a data-grade tape.
     70 The drive has not been able to read the MRS (Media Recognition\
     71 System) stripes. MRS stripes are pre-defined stripes at BOM to\
     72 identify the media. Media may be audio/video grade and is not for\
     73 a data streaming device.
     74 
     75 SSC2
     76 0x9
     77 Write protect
     78 Critical
     79 You are trying to write to a write protected cartridge. Remove\
     80 the write protection or use another tape.
     81 Write command attempted a write to a write protected tape.
     82 
     83 SSC2
     84 0xa
     85 No removal
     86 Information
     87 You cannot eject the cartridge because the tape drive is in use.\
     88 Wait until the operation is complete before ejecting the cartridge.
     89 Manual or software unload attempted when prevent media removal\
     90 is on.
     91 
     92 SSC2
     93 0xb
     94 Cleaning media
     95 Information
     96 The tape in the drive is a cleaning cartridge.
     97 Cleaning tape loaded into drive.
     98 
     99 SSC2
    100 0xc
    101 Unsupported format
    102 Information
    103 You have tried to load a cartridge of a type that is not supported\
    104 by this drive.
    105 Attempted load of unsupported tape format (e.g., DDS2 in DDS1\
    106 drive).
    107 
    108 SSC2
    109 0xd
    110 Recoverable snapped tape
    111 Critical
    112 The operation has failed because the tape in the drive has\
    113 snapped:\
    114 1. Discard the old tape.\
    115 2. Restart the operation with a different tape.
    116 Tape snapped/cut in the drive where media can be ejected.
    117 
    118 SSC2
    119 0xe
    120 Unrecoverable snapped tape
    121 Critical
    122 The operation has failed because the tape in the drive has\
    123 snapped:\
    124 1. Do not attempt to extract the tape cartridge.\
    125 2. Call the tape drive supplier help line.
    126 Tape snapped/cut in the drive where media cannot be ejected.
    127 
    128 SSC2
    129 0xf
    130 Memory chip in cartridge failure
    131 Warning
    132 The memory in the tape cartridge has failed, which reduces\
    133 performance. Do not use the cartridge for further write operations.
    134 Memory chip failed in cartridge.
    135 
    136 SSC2
    137 0x10
    138 Forced eject
    139 Critical
    140 The operation has failed because the tape cartridge was manually\
    141 de-mounted while the tape drive was actively writing or reading.
    142 Manual or forced eject while drive actively writing or reading.
    143 
    144 SSC2
    145 0x11
    146 Read only format
    147 Warning
    148 You have loaded a cartridge of a type that is read-only in this\
    149 drive. The cartridge will appear as write protected.
    150 Media loaded that is read-only format.
    151 
    152 SSC2
    153 0x12
    154 Tape directory corrupted on load
    155 Warning
    156 The tape directory on the tape cartridge has been corrupted. File\
    157 search performance will be degraded. The tape directory can be\
    158 rebuilt by reading all the data on the cartridge.
    159 Tape drive powered down with tape loaded, or permanent error\
    160 prevented the tape directory being updated.
    161 
    162 SSC2
    163 0x13
    164 Nearing media life
    165 Information
    166 The tape cartridge is nearing the end of its calculated life.\
    167 It is recommended that you:\
    168 1. Use another tape cartridge for your next backup.\
    169 2. Store this tape cartridge in a safe place in case you need\
    170    to restore data from it.
    171 Media may have exceeded its specified number of passes.
    172 
    173 SSC2
    174 0x14
    175 Clean now
    176 Critical
    177 The tape drive needs cleaning:\
    178 1. If the operation has stopped, eject the tape and clean the\
    179    drive.\
    180 2. If the operation has not stopped, wait for it to finish and\
    181    then clean the drive.\
    182 Check the tape drive users manual for device specific cleaning\
    183 instructions.
    184 The drive has a head clog or needs cleaning.
    185 
    186 SSC2
    187 0x15
    188 Clean periodic
    189 Warning
    190 The tape drive is due for routine cleaning:\
    191 1. Wait for the current operation to finish.\
    192 2. Then use a cleaning cartridge.\
    193 Check the tape drive users manual for device specific cleaning\
    194 instructions.
    195 The drive is ready for a periodic cleaning.
    196 
    197 SSC2
    198 0x16
    199 Expired cleaning media
    200 Critical
    201 The last cleaning cartridge used in the tape drive has worn out:\
    202 1. Discard the worn out cleaning cartridge.\
    203 2. Wait for the current operation to finish.\
    204 3. Then use a new cleaning cartridge.
    205 The cleaning tape has expired.
    206 
    207 SSC2
    208 0x17
    209 Invalid cleaning tape
    210 Critical
    211 The last cleaning cartridge used in the tape drive was an invalid\
    212 type:\
    213 1. Do not use this cleaning cartridge in this drive.\
    214 2. Wait for the current operation to finish.\
    215 3. Then use a valid cleaning cartridge.
    216 Invalid cleaning tape type used.
    217 
    218 SSC2
    219 0x18
    220 Retension requested
    221 Warning
    222 The tape drive has requested a retension operation.
    223 The drive is having severe trouble reading or writing, that will\
    224 be resolved by a retension cycle.
    225 
    226 SSC2
    227 0x19
    228 Dual-port interface error
    229 Warning
    230 A redundant interface port on the tape drive has failed.
    231 Failure of one interface port in a dual-port configuration (i.e.,\
    232 Fibre Channel)
    233 
    234 SSC2
    235 0x1a
    236 Cooling fan failure
    237 Warning
    238 A tape drive cooling fan has failed.
    239 Fan failure inside tape drive mechanism or tape drive enclosure.
    240 
    241 SSC2
    242 0x1b
    243 Power supply failure
    244 Warning
    245 A redundant power supply has failed inside the tape drive\
    246 enclosure. Check the enclosure users manual for instructions on\
    247 replacing the failed power supply.
    248 Redundant PSU failure inside the tape drive enclosure or rack\
    249 subsystem.
    250 
    251 SSC2
    252 0x1c
    253 Power consumption
    254 Warning
    255 The tape drive power consumption is outside the specified range.
    256 Power consumption of the tape drive is outside specified range.
    257 
    258 SSC2
    259 0x1d
    260 Drive maintenance
    261 Warning
    262 Preventive maintenance of the tape drive is required. Check the\
    263 tape drive users manual for device specific preventive maintenance\
    264 tasks or call the tape drive supplier help line.
    265 The drive requires preventive maintenance (not cleaning).
    266 
    267 SSC2
    268 0x1e
    269 Hardware A
    270 Critical
    271 The tape drive has a hardware fault:\
    272 1. Eject the tape or magazine.\
    273 2. Reset the drive.\
    274 3. If the problem persists, call the tape drive supplier help line.
    275 The drive has a hardware fault that requires reset to recover.
    276 
    277 SSC2
    278 0x1f
    279 Hardware B
    280 Critical
    281 The tape drive has a hardware fault:\
    282 1. Turn the tape drive off and then on again.\
    283 2. Restart the operation.\
    284 3. If the problem persists, call the tape drive supplier help line.
    285 The drive has a hardware fault that is not read/write related or\
    286 requires a power cycle to recover.
    287 
    288 SSC2
    289 0x20
    290 Interface
    291 Warning
    292 The tape drive has a problem with the application client\
    293 interface:\
    294 1. Check the cables and cable connections.\
    295 2. Restart the operation.
    296 The drive has identified an interface fault.
    297 
    298 SSC2
    299 0x21
    300 Eject media
    301 Critical
    302 The operation has failed:\
    303 1. Eject the tape or magazine.\
    304 2. Insert the tape or magazine again.\
    305 3. Restart the operation.
    306 Failed to finish mounting.
    307 
    308 SSC2
    309 0x22
    310 Download fail
    311 Warning
    312 The firmware download has failed because you have tried to use\
    313 the incorrect firmware for this tape drive. Obtain the correct\
    314 firmware and try again.
    315 Firmware download failed.
    316 
    317 SSC2
    318 0x23
    319 Drive humidity
    320 Warning
    321 Environmental conditions inside the tape drive are outside the\
    322 specified humidity range.
    323 Drive humidity limits exceeded.
    324 
    325 SSC2
    326 0x24
    327 Drive temperature
    328 Warning
    329 Environmental conditions inside the tape drive are outside the\
    330 specified temperature range.
    331 Drive temperature limits exceeded.
    332 
    333 SSC2
    334 0x25
    335 Drive voltage
    336 Warning
    337 The voltage supply to the tape drive is outside the specified\
    338 range.
    339 Drive voltage limits exceeded.
    340 
    341 SSC2
    342 0x26
    343 Predictive failure
    344 Critical
    345 A hardware failure of the tape drive is predicted. Call the tape\
    346 drive supplier help line.
    347 Predictive failure of drive hardware.
    348 
    349 SSC2
    350 0x27
    351 Diagnostics required
    352 Warning
    353 The tape drive may have a hardware fault. Run extended diagnostics\
    354 to verify and diagnose the problem. Check the tape drive users\
    355 manual for device specific instructions on running extended\
    356 diagnostics tests.
    357 The drive may have a hardware fault that may be identified by\
    358 extended diagnostics (i.e. SEND DIAGNOSTIC command).
    359 
    360 SSC2
    361 0x28
    362 Loader hardware A
    363 Critical
    364 The changer mechanism is having difficulty communicating with the\
    365 tape drive:\
    366 1. Turn the autoloader off then on.\
    367 2. Restart the operation.\
    368 3. If a problem persists, call the tape drive supplier help line.
    369 Loader mechanism is having trouble communicating with the tape\
    370 drive.
    371 
    372 SSC2
    373 0x29
    374 Loader stray tape
    375 Critical
    376 A tape has been left in the autoloader by a previous hardware\
    377 fault:\
    378 1. Insert an empty magazine to clear the fault.\
    379 2. If the fault does not clear, turn the autoloader off and then\
    380    on again.\
    381 3. If the problem persists, call the tape drive supplier help line.
    382 Stray tape left in loader after previous error recovery.
    383 
    384 SSC2
    385 0x2a
    386 Loader hardware B
    387 Warning
    388 There is a problem with the autoloader mechanism.
    389 Loader mechanism has a hardware fault.
    390 
    391 SSC2
    392 0x2b
    393 Loader door
    394 Critical
    395 The operation has failed because the autoloader door is open:\
    396 1. Clear any obstructions from the autoloader door.\
    397 2. Eject the magazine and then insert it again.\
    398 3. If the fault does not clear, turn the autoloader off and then\
    399    on again.\
    400 4. If the problem persists, call the tape drive supplier help line.
    401 Tape changer door open.
    402 
    403 SSC2
    404 0x2c
    405 Loader hardware C
    406 Critical
    407 The autoloader has a hardware fault:\
    408 1. Turn the autoloader off and then on again.\
    409 2. Restart the operation.\
    410 3. If the problem persists, call the tape drive supplier help\
    411    line.\
    412 Check the autoloader users manual for device specific instructions\
    413 on turning the device power on and off.
    414 The loader mechanism has a hardware fault that is not mechanically related.
    415 
    416 SSC2
    417 0x2d
    418 Loader magazine
    419 Critical
    420 The autoloader cannot operate without the magazine:\
    421 1. Insert the magazine into the autoloader.\
    422 2. Restart the operation.
    423 Loader magazine not present.
    424 
    425 SSC2
    426 0x2e
    427 Loader predictive failure
    428 Warning
    429 A hardware failure of the changer mechanism is predicted. Call\
    430 the tape drive supplier help line.
    431 Predictive failure of loader mechanism hardware.
    432 
    433 SSC2
    434 0x2f
    435 Reserved
    436 Reserved
    437 ""
    438 ""
    439 
    440 SSC2
    441 0x30
    442 Reserved
    443 Reserved
    444 ""
    445 ""
    446 
    447 SSC2
    448 0x31
    449 Reserved
    450 Reserved
    451 ""
    452 ""
    453 
    454 SSC2
    455 0x32
    456 Lost statistics
    457 Warning
    458 Media statistics have been lost at some time in the past.
    459 Drive or library powered down with tape loaded.
    460 
    461 SSC2
    462 0x33
    463 Tape directory invalid at unload
    464 Warning
    465 The tape directory on the tape cartridge just unloaded has been\
    466 corrupted. File search performance will be degraded. The tape\
    467 directory can be rebuilt by reading all the data.
    468 Error preventing the tape directory being updated on unload.
    469 
    470 SSC2
    471 0x34
    472 Tape system area write failure
    473 Critical
    474 The tape just unloaded could not write its system area\
    475 successfully:\
    476 1. Copy data to another tape cartridge.\
    477 2. Discard the old cartridge.
    478 Write errors while writing the system area on unload.
    479 
    480 SSC2
    481 0x35
    482 Tape system area read failure
    483 Critical
    484 The tape system area could not be read successfully at load time:\
    485 1. Copy data to another tape cartridge.
    486 Read errors while reading the system area on load.
    487 
    488 SSC2
    489 0x36
    490 No start of data
    491 Critical
    492 The start of data could not be found on the tape:\
    493 1. Check that you are using the correct format tape.\
    494 2. Discard the tape or return the tape to your supplier.
    495 Tape damaged, bulk erased, or incorrect format.
    496 
    497 SSC2
    498 0x37
    499 Loading failure
    500 Critical
    501 The operation has failed because the media cannot be loaded and\
    502 threaded.\
    503 1. Remove the cartridge, inspect it as specified in the product\
    504    manual, and retry the operation.\
    505 2. If the problem persists, call the tape drive supplier help line.
    506 The drive is unable to load the media and thread the tape.
    507 
    508 SSC3
    509 0x38
    510 Unrecoverable unload failure
    511 Critical
    512 The operation has failed because the medium cannot be unloaded:\
    513 1. Do not attempt to extract the tape cartridge.\
    514 2. Call the tape driver supplier help line.
    515 The drive is unable to unload the medium.
    516 
    517 SSC2
    518 0x38
    519 Reserved
    520 Reserved
    521 ""
    522 ""
    523 
    524 SSC3
    525 0x39
    526 Automation interface failure
    527 Critical
    528 The tape drive has a problem with the automation interface:\
    529 1. Check the power to the automation system.\
    530 2. Check the cables and cable connections.\
    531 3. Call the supplier help line if problem persists.
    532 The drive has identified an interface fault.
    533 
    534 SSC2
    535 0x39
    536 Reserved
    537 Reserved
    538 ""
    539 ""
    540 
    541 SSC3
    542 0x3a
    543 Firmware failure
    544 Warning
    545 The tape drive has reset itself due to a detected firmware fault. If\
    546 problem persists, call the supplier help line.
    547 Firmware bug.
    548 
    549 SSC2
    550 0x3a
    551 Reserved
    552 Reserved
    553 ""
    554 ""
    555 
    556 SSC3
    557 0x3b
    558 WORM medium integrity check failed
    559 Warning
    560 The tape drive has detected an inconsistency during the WORM medium\
    561 integrity checks. Someone may have tampered with the cartridge.
    562 Someone has tampered with the WORM medium.
    563 
    564 SSC2
    565 0x3b
    566 Reserved
    567 Reserved
    568 ""
    569 ""
    570 
    571 SSC3
    572 0x3c
    573 WORM medium overwrite attempted
    574 Warning
    575 An attempt had been made to overwrite user data on a WORM medium:\ 
    576 1. If a WORM medium was used inadvertently, replace it with a\
    577    normal data medium.\
    578 2. If a WORM medium was used intentionally:\
    579    a) check that the software application is compatible with the\
    580       WORM medium format you are using.\
    581    b) check that the medium is bar-coded correctly for WORM.
    582 The application software does not recognize the medium as WORM.
    583 
    584 SSC2
    585 0x3c
    586 Reserved
    587 Reserved
    588 ""
    589 ""
    590 
    591 SSC2
    592 0x3d
    593 Reserved
    594 Reserved
    595 ""
    596 ""
    597 
    598 SSC2
    599 0x3e
    600 Reserved
    601 Reserved
    602 ""
    603 ""
    604 
    605 SSC2
    606 0x3f
    607 Reserved
    608 Reserved
    609 ""
    610 ""
    611 
    612 SSC2
    613 0x40
    614 Reserved
    615 Reserved
    616 ""
    617 ""
    618 
    619 SMC2
    620 0x1
    621 Library hardware A
    622 Critical
    623 The library mechanism is having difficulty communicating with\
    624 the drive:\
    625 1. Turn the library off then on.\
    626 2. Restart the operation.\
    627 3. If the problem persists, call the library supplier help line.
    628 Changer mechanism is having trouble communicating with the\
    629 internal drive.
    630 
    631 SMC2
    632 0x2
    633 Library hardware B
    634 Warning
    635 There is a problem with the library mechanism. If problem\
    636 persists, call the library supplier help line.
    637 Changer mechanism has a hardware fault.
    638 
    639 SMC2
    640 0x3
    641 Library hardware C
    642 Critical
    643 The library has a hardware fault:\
    644 1. Reset the library.\
    645 2. Restart the operation.\
    646 Check the library users manual for device specific instructions\
    647 on resetting the device.
    648 The changer mechanism has a hardware fault that requires a reset\
    649 to recover.
    650 
    651 SMC2
    652 0x4
    653 Library hardware D
    654 Critical
    655 The library has a hardware fault:\
    656 1. Turn the library off then on again.\
    657 2. Restart the operation.\
    658 3. If the problem persists, call the library supplier help line.\
    659 Check the library users manual for device specific instructions\
    660 on turning the device power on and off.
    661 The changer mechanism has a hardware fault that is not\
    662 mechanically related or requires a power cycle to recover.
    663 
    664 SMC2
    665 0x5
    666 Library diagnostics required
    667 Warning
    668 The library mechanism may have a hardware fault. Run extended\
    669 diagnostics to verify and diagnose the problem. Check the library\
    670 users manual for device specific instructions on running extended\
    671 diagnostics test.
    672 The changer mechanism may have a hardware fault which would be\
    673 identified by extended diagnostics.
    674 
    675 SMC2
    676 0x6
    677 Library interface
    678 Critical
    679 The library has a problem with the host interface:\
    680 1. Check the cables and connections.\
    681 2. Restart the operation.
    682 The library has identified an interface fault.
    683 
    684 SMC2
    685 0x7
    686 Predictive failure
    687 Warning
    688 A hardware failure of the library is predicted. Call the library\
    689 supplier help line.
    690 Predictive failure of library hardware.
    691 
    692 SMC2
    693 0x8
    694 Library maintenance
    695 Warning
    696 Preventive maintenance of the library is required. Check the\
    697 library users manual for device specific preventative maintenance\
    698 tasks, or call your library supplier help line.
    699 Library preventative maintenance required.
    700 
    701 SMC2
    702 0x9
    703 Library humidity limits
    704 Critical
    705 General environmental conditions inside the library are outside\
    706 the specified humidity range.
    707 Library humidity limits exceeded.
    708 
    709 SMC2
    710 0xa
    711 Library temperature limits
    712 Critical
    713 General environmental conditions inside the library are outside\
    714 the specified temperature range.
    715 Library temperature limits exceeded.
    716 
    717 SMC2
    718 0xb
    719 Library voltage limits
    720 Critical
    721 The voltage supply to the library is outside the specified range.\
    722 There is a potential problem with the power supply or failure of\
    723 a redundant power supply.
    724 Library voltage limits exceeded.
    725 
    726 SMC2
    727 0xc
    728 Library stray tape
    729 Critical
    730 A cartridge has been left inside the library by a previous\
    731 hardware fault:\
    732 1. Insert an empty magazine to clear the fault.\
    733 2. If the fault does not clear, turn the library off and then\
    734    on again.\
    735 3. If the problem persists, call the library supplier help line.
    736 Stray cartridge left in library after previous error recovery.
    737 
    738 SMC2
    739 0xd
    740 Library pick retry
    741 Warning
    742 There is a potential problem with the drive ejecting cartridges\
    743 or with the library mechanism picking a cartridge from a slot.\
    744 1. No action needs to be taken at this time.\
    745 2. If the problem persists, call the library supplier help line.
    746 Operation to pick a cartridge from a slot had to perform an\
    747 excessive number of retries before succeeding.
    748 
    749 SMC2
    750 0xe
    751 Library place retry
    752 Warning
    753 There is a potential problem with the library mechanism placing\
    754 a cartridge into a slot.\
    755 1. No action needs to be taken at this time.\
    756 2. If the problem persists, call the library supplier help line.
    757 Operation to place a cartridge in a slot had to perform an\
    758 excessive number of retries before succeeding.
    759 
    760 SMC2
    761 0xf
    762 Library load retry
    763 Warning
    764 There is a potential problem with the drive or the library\
    765 mechanism loading cartridges, or an incompatible cartridge.
    766 Operation to load a cartridge in a drive had to perform an\
    767 excessive number of retries before succeeding.
    768 
    769 SMC2
    770 0x10
    771 Library door
    772 Critical
    773 The library has failed because the door is open:\
    774 1. Clear any obstructions from the library door.\
    775 2. Close the library door.\
    776 3. If the problem persists, call the library supplier help line.
    777 Changer door open prevents library functioning.
    778 
    779 SMC2
    780 0x11
    781 Library mail-slot
    782 Critical
    783 There is a mechanical problem with the library media import/export\
    784 mail-slot.
    785 Mechanical problem with import/export mail-slot.
    786 
    787 SMC2
    788 0x12
    789 Library magazine
    790 Critical
    791 The library can not operate without the magazine.\
    792 1. Insert the magazine into the library.\
    793 2. Restart the operation.
    794 Library magazine not present.
    795 
    796 SMC2
    797 0x13
    798 Library security
    799 Warning
    800 Library security has been compromised.
    801 Library door opened then closed during operation.
    802 
    803 SMC2
    804 0x14
    805 Library security mode
    806 Information
    807 The library security mode has been changed. The library has\
    808 either been put into secure mode, or the library has exited the\
    809 secure mode. This is for information purposes only. No action\
    810 is required.
    811 Library security mode changed.
    812 
    813 SMC2
    814 0x15
    815 Library off-line
    816 Information
    817 The library has been manually turned off-line and is unavailable\
    818 for use.
    819 Library manually turned off-line.
    820 
    821 SMC2
    822 0x16
    823 Library drive off-line
    824 Information
    825 A drive inside the library has been taken off-line. This is for\
    826 information purposes only. No action is required.
    827 Library turned internal drive off-line.
    828 
    829 SMC2
    830 0x17
    831 Library scan retry
    832 Warning
    833 There is a potential problem with the bar code label or the\
    834 scanner hardware in the library mechanism.\
    835 1. No action needs to be taken at this time.\
    836 2. If the problem persists, call the library supplier help line.
    837 Operation to scan the bar code on a cartridge had to perform and\
    838 excessive number of retries before succeeding.
    839 
    840 SMC2
    841 0x18
    842 Library inventory
    843 Critical
    844 The library has detected an inconsistency in its inventory.\
    845 1. Redo the library inventory to correct inconsistency.\
    846 2. Restart the operation.\
    847 Check the applications users manual or the hardware users manual\
    848 for specific instructions on redoing the library inventory.
    849 Inconsistent media inventory.
    850 
    851 SMC2
    852 0x19
    853 Library illegal operation
    854 Warning
    855 A library operation has been attempted that is invalid at this\
    856 time.
    857 Illegal operation detected.
    858 
    859 SMC2
    860 0x1a
    861 Dual-port interface error
    862 Warning
    863 A redundant interface port on the library has failed.
    864 Failure of one interface port in a dual-port configuration.
    865 
    866 SMC2
    867 0x1b
    868 Cooling fan failure
    869 Warning
    870 A library cooling fan has failed.
    871 One or more fans inside the library have failed. Internal flag\
    872 state only cleared when all flags are working again.
    873 
    874 SMC2
    875 0x1c
    876 Power supply
    877 Warning
    878 A redundant power supply has failed inside the library. Check the\
    879 library users manual for instructions on replacing the failed\
    880 power supply.
    881 Redundant power supply failure inside the library subsystem.
    882 
    883 SMC2
    884 0x1d
    885 Power consumption
    886 Warning
    887 The library power consumption is outside the specified range.
    888 Power consumption of one or more devices inside the library is\
    889 outside the specified range.
    890 
    891 SMC2
    892 0x1e
    893 Pass-through mechanism failure
    894 Critical
    895 A failure has occurred in the cartridge pass-through mechanism\
    896 between two library modules.
    897 Error occurred in pass-through mechanism during self test or\
    898 while attempting to transfer a cartridge between library modules.
    899 
    900 SMC2
    901 0x1f
    902 Cartridge in pass-through mechanism
    903 Critical
    904 A cartridge has been left in the pass-through mechanism from a\
    905 previous hardware fault. Check the library users guide for\
    906 instructions on clearing this fault.
    907 Cartridge left in the pass-through mechanism between two library\
    908 modules.
    909 
    910 SMC2
    911 0x20
    912 Unreadable bar code labels
    913 Information
    914 The library was unable to read the bar code on a cartridge.
    915 Unable to read a bar code label on a cartridge during library\
    916 inventory/scan.
    917 
    918 SMC2
    919 0x21
    920 Reserved
    921 Reserved
    922 ""
    923 ""
    924 
    925 SMC2
    926 0x22
    927 Reserved
    928 Reserved
    929 ""
    930 ""
    931 
    932 SMC2
    933 0x23
    934 Reserved
    935 Reserved
    936 ""
    937 ""
    938 
    939 SMC2
    940 0x24
    941 Reserved
    942 Reserved
    943 ""
    944 ""
    945 
    946 SMC2
    947 0x25
    948 Reserved
    949 Reserved
    950 ""
    951 ""
    952 
    953 SMC2
    954 0x26
    955 Reserved
    956 Reserved
    957 ""
    958 ""
    959 
    960 SMC2
    961 0x27
    962 Reserved
    963 Reserved
    964 ""
    965 ""
    966 
    967 SMC2
    968 0x28
    969 Reserved
    970 Reserved
    971 ""
    972 ""
    973 
    974 SMC2
    975 0x29
    976 Reserved
    977 Reserved
    978 ""
    979 ""
    980 
    981 SMC2
    982 0x2a
    983 Reserved
    984 Reserved
    985 ""
    986 ""
    987 
    988 SMC2
    989 0x2b
    990 Reserved
    991 Reserved
    992 ""
    993 ""
    994 
    995 SMC2
    996 0x2c
    997 Reserved
    998 Reserved
    999 ""
   1000 ""
   1001 
   1002 SMC2
   1003 0x2d
   1004 Reserved
   1005 Reserved
   1006 ""
   1007 ""
   1008 
   1009 SMC2
   1010 0x2e
   1011 Reserved
   1012 Reserved
   1013 ""
   1014 ""
   1015 
   1016 SMC2
   1017 0x2f
   1018 Reserved
   1019 Reserved
   1020 ""
   1021 ""
   1022 
   1023 SMC2
   1024 0x30
   1025 Reserved
   1026 Reserved
   1027 ""
   1028 ""
   1029 
   1030 SMC2
   1031 0x31
   1032 Reserved
   1033 Reserved
   1034 ""
   1035 ""
   1036 
   1037 SMC2
   1038 0x32
   1039 Reserved
   1040 Reserved
   1041 ""
   1042 ""
   1043 
   1044 SMC2
   1045 0x33
   1046 Reserved
   1047 Reserved
   1048 ""
   1049 ""
   1050 
   1051 SMC2
   1052 0x34
   1053 Reserved
   1054 Reserved
   1055 ""
   1056 ""
   1057 
   1058 SMC2
   1059 0x35
   1060 Reserved
   1061 Reserved
   1062 ""
   1063 ""
   1064 
   1065 SMC2
   1066 0x36
   1067 Reserved
   1068 Reserved
   1069 ""
   1070 ""
   1071 
   1072 SMC2
   1073 0x37
   1074 Reserved
   1075 Reserved
   1076 ""
   1077 ""
   1078 
   1079 SMC2
   1080 0x38
   1081 Reserved
   1082 Reserved
   1083 ""
   1084 ""
   1085 
   1086 SMC2
   1087 0x38
   1088 Reserved
   1089 Reserved
   1090 ""
   1091 ""
   1092 
   1093 SMC2
   1094 0x39
   1095 Reserved
   1096 Reserved
   1097 ""
   1098 ""
   1099 
   1100 SMC2
   1101 0x3a
   1102 Reserved
   1103 Reserved
   1104 ""
   1105 ""
   1106 
   1107 SMC2
   1108 0x3b
   1109 Reserved
   1110 Reserved
   1111 ""
   1112 ""
   1113 
   1114 SMC2
   1115 0x3c
   1116 Reserved
   1117 Reserved
   1118 ""
   1119 ""
   1120 
   1121 SMC2
   1122 0x3d
   1123 Reserved
   1124 Reserved
   1125 ""
   1126 ""
   1127 
   1128 SMC2
   1129 0x3e
   1130 Reserved
   1131 Reserved
   1132 ""
   1133 ""
   1134 
   1135 SMC2
   1136 0x3f
   1137 Reserved
   1138 Reserved
   1139 ""
   1140 ""
   1141 
   1142 SMC2
   1143 0x40
   1144 Reserved
   1145 Reserved
   1146 ""
   1147 ""
   1148 
   1149