Home | History | Annotate | Download | only in dicts
      1 #
      2 # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
      3 # Use is subject to license terms.
      4 #
      5 # CDDL HEADER START
      6 #
      7 # The contents of this file are subject to the terms of the
      8 # Common Development and Distribution License (the "License").
      9 # You may not use this file except in compliance with the License.
     10 #
     11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
     12 # or http://www.opensolaris.org/os/licensing.
     13 # See the License for the specific language governing permissions
     14 # and limitations under the License.
     15 #
     16 # When distributing Covered Code, include this CDDL HEADER in each
     17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
     18 # If applicable, add the following below this CDDL HEADER, with the
     19 # fields enclosed by brackets "[]" replaced with your own identifying
     20 # information: Portions Copyright [yyyy] [name of copyright owner]
     21 #
     22 # CDDL HEADER END
     23 #
     24 # DO NOT EDIT -- this file is generated by the Event Registry.
     25 #
     26 #
     27 # code: SUNOS-8000-0G
     28 # keys: ereport.sunos.unix.fm_panic
     29 #
     30 msgid "SUNOS-8000-0G.type"
     31 msgstr "Error"
     32 msgid "SUNOS-8000-0G.severity"
     33 msgstr "Major"
     34 msgid "SUNOS-8000-0G.description"
     35 msgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
     36 msgid "SUNOS-8000-0G.response"
     37 msgstr "Solaris will attempt to save and diagnose the error telemetry"
     38 msgid "SUNOS-8000-0G.impact"
     39 msgstr "The system will sync files, save a crash dump if needed, and reboot"
     40 msgid "SUNOS-8000-0G.action"
     41 msgstr "Save the error summary below in case telemetry cannot be saved"
     42 #
     43 # code: SUNOS-8000-1L
     44 # keys: defect.sunos.eft.undiagnosable_problem
     45 #
     46 msgid "SUNOS-8000-1L.type"
     47 msgstr "Defect"
     48 msgid "SUNOS-8000-1L.severity"
     49 msgstr "Minor"
     50 msgid "SUNOS-8000-1L.description"
     51 msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
     52 msgid "SUNOS-8000-1L.response"
     53 msgstr "Error reports from the component will be logged for examination by Sun."
     54 msgid "SUNOS-8000-1L.impact"
     55 msgstr "Automated diagnosis and response for these events will not occur."
     56 msgid "SUNOS-8000-1L.action"
     57 msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support."
     58 #
     59 # code: SUNOS-8000-20
     60 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
     61 #
     62 msgid "SUNOS-8000-20.type"
     63 msgstr "Fault"
     64 msgid "SUNOS-8000-20.severity"
     65 msgstr "Critical"
     66 msgid "SUNOS-8000-20.description"
     67 msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
     68 msgid "SUNOS-8000-20.response"
     69 msgstr "One or more of device instances may be disabled"
     70 msgid "SUNOS-8000-20.impact"
     71 msgstr "Loss of services provided by the device instances associated with this fault"
     72 msgid "SUNOS-8000-20.action"
     73 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
     74 #
     75 # code: SUNOS-8000-3V
     76 # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
     77 #
     78 msgid "SUNOS-8000-3V.type"
     79 msgstr "Fault"
     80 msgid "SUNOS-8000-3V.severity"
     81 msgstr "Critical"
     82 msgid "SUNOS-8000-3V.description"
     83 msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
     84 msgid "SUNOS-8000-3V.response"
     85 msgstr "One or more of device instances may be disabled"
     86 msgid "SUNOS-8000-3V.impact"
     87 msgstr "Loss of services provided by the device instances associated with this fault"
     88 msgid "SUNOS-8000-3V.action"
     89 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
     90 #
     91 # code: SUNOS-8000-46
     92 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
     93 #
     94 msgid "SUNOS-8000-46.type"
     95 msgstr "Fault"
     96 msgid "SUNOS-8000-46.severity"
     97 msgstr "Critical"
     98 msgid "SUNOS-8000-46.description"
     99 msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
    100 msgid "SUNOS-8000-46.response"
    101 msgstr "One or more of device instances may be disabled"
    102 msgid "SUNOS-8000-46.impact"
    103 msgstr "Loss of services provided by the device instances associated with this fault"
    104 msgid "SUNOS-8000-46.action"
    105 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
    106 #
    107 # code: SUNOS-8000-5T
    108 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
    109 #
    110 msgid "SUNOS-8000-5T.type"
    111 msgstr "Fault"
    112 msgid "SUNOS-8000-5T.severity"
    113 msgstr "Critical"
    114 msgid "SUNOS-8000-5T.description"
    115 msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
    116 msgid "SUNOS-8000-5T.response"
    117 msgstr "One or more of device instances may be disabled"
    118 msgid "SUNOS-8000-5T.impact"
    119 msgstr "Loss of services provided by the device instances associated with this fault"
    120 msgid "SUNOS-8000-5T.action"
    121 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
    122 #
    123 # code: SUNOS-8000-69
    124 # keys: defect.Deprecated fault.io.pci.device
    125 #
    126 msgid "SUNOS-8000-69.type"
    127 msgstr "Fault"
    128 msgid "SUNOS-8000-69.severity"
    129 msgstr "Critical"
    130 msgid "SUNOS-8000-69.description"
    131 msgstr "A problem was detected for a PCI controller  Refer to %s for more information."
    132 msgid "SUNOS-8000-69.response"
    133 msgstr "One or more of device instances may be disabled"
    134 msgid "SUNOS-8000-69.impact"
    135 msgstr "Loss of services provided by the device instances associated with this fault."
    136 msgid "SUNOS-8000-69.action"
    137 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
    138 #
    139 # code: SUNOS-8000-7N
    140 # keys: defect.Deprecated fault.io.pci.bus
    141 #
    142 msgid "SUNOS-8000-7N.type"
    143 msgstr "Fault"
    144 msgid "SUNOS-8000-7N.severity"
    145 msgstr "Critical"
    146 msgid "SUNOS-8000-7N.description"
    147 msgstr "A problem was detected for a PCI bus  Refer to %s for more information."
    148 msgid "SUNOS-8000-7N.response"
    149 msgstr "One or more of device instances may be disabled"
    150 msgid "SUNOS-8000-7N.impact"
    151 msgstr "Loss of services provided by the device instances associated with this fault."
    152 msgid "SUNOS-8000-7N.action"
    153 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
    154 #
    155 # code: SUNOS-8000-8W
    156 # keys: defect.Deprecated defect.io.pci.driver
    157 #
    158 msgid "SUNOS-8000-8W.type"
    159 msgstr "Fault"
    160 msgid "SUNOS-8000-8W.severity"
    161 msgstr "Critical"
    162 msgid "SUNOS-8000-8W.description"
    163 msgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
    164 msgid "SUNOS-8000-8W.response"
    165 msgstr "One or more of device instances may be disabled"
    166 msgid "SUNOS-8000-8W.impact"
    167 msgstr "Loss of services provided by the device instances associated with this fault."
    168 msgid "SUNOS-8000-8W.action"
    169 msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
    170 #
    171 # code: SUNOS-8000-91
    172 # keys: defect.sunos.zones.upgrade
    173 #
    174 msgid "SUNOS-8000-91.type"
    175 msgstr "Defect"
    176 msgid "SUNOS-8000-91.severity"
    177 msgstr "Minor"
    178 msgid "SUNOS-8000-91.description"
    179 msgstr "\n	The Solaris system or boot environment that is being upgraded\n	has non-global zones installed.  The current version of Live\n	Upgrade cannot upgrade a boot environment that has non-global\n	zones installed.\n	  Refer to %s for more information."
    180 msgid "SUNOS-8000-91.response"
    181 msgstr "The upgrade procedure has been terminated."
    182 msgid "SUNOS-8000-91.impact"
    183 msgstr "The Solaris system or boot environment is not upgraded."
    184 msgid "SUNOS-8000-91.action"
    185 msgstr "\n	Evaluate each of the choices below and select the one that is\n	best for your needs.  Contact Sun for support.\n	"
    186 #
    187 # code: SUNOS-8000-AK
    188 # keys: ereport.sunos.boot.upgrade.menu_lst
    189 #
    190 msgid "SUNOS-8000-AK.type"
    191 msgstr "Error"
    192 msgid "SUNOS-8000-AK.severity"
    193 msgstr "Critical"
    194 msgid "SUNOS-8000-AK.description"
    195 msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
    196 msgid "SUNOS-8000-AK.response"
    197 msgstr "No automated response.\n"
    198 msgid "SUNOS-8000-AK.impact"
    199 msgstr "Future reboots could fail until this problem is corrected.\n"
    200 msgid "SUNOS-8000-AK.action"
    201 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details.\n"
    202 #
    203 # code: SUNOS-8000-CF
    204 # keys: ereport.sunos.boot.upgrade.menu_lst_bfu
    205 #
    206 msgid "SUNOS-8000-CF.type"
    207 msgstr "Error"
    208 msgid "SUNOS-8000-CF.severity"
    209 msgstr "Critical"
    210 msgid "SUNOS-8000-CF.description"
    211 msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
    212 msgid "SUNOS-8000-CF.response"
    213 msgstr "No automated response.\n"
    214 msgid "SUNOS-8000-CF.impact"
    215 msgstr "Future reboots could fail until this problem is corrected.\n"
    216 msgid "SUNOS-8000-CF.action"
    217 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details.\n"
    218 #
    219 # code: SUNOS-8000-DM
    220 # keys: defect.sunos.smf.svc.maintenance
    221 #
    222 msgid "SUNOS-8000-DM.type"
    223 msgstr "Defect"
    224 msgid "SUNOS-8000-DM.severity"
    225 msgstr "Major"
    226 msgid "SUNOS-8000-DM.description"
    227 msgstr "A service failed and could not be restarted.  Refer to %s for more information."
    228 msgid "SUNOS-8000-DM.response"
    229 msgstr "The service has been placed into the maintenance state."
    230 msgid "SUNOS-8000-DM.impact"
    231 msgstr "The service is unavailable."
    232 msgid "SUNOS-8000-DM.action"
    233 msgstr "Run svcs -x to determine why the service failed and the location of logfiles, if any."
    234 #
    235 # code: SUNOS-8000-E8
    236 # keys: defect.sunos.eft.undiag.checkpoint
    237 #
    238 msgid "SUNOS-8000-E8.type"
    239 msgstr "Defect"
    240 msgid "SUNOS-8000-E8.severity"
    241 msgstr "Minor"
    242 msgid "SUNOS-8000-E8.description"
    243 msgstr "The diagnosis engine encountered an error while resuming diagnosis.  Refer to %s for more information."
    244 msgid "SUNOS-8000-E8.response"
    245 msgstr "Error reports have been logged for examination by Sun."
    246 msgid "SUNOS-8000-E8.impact"
    247 msgstr "Automated diagnosis and response for these events will not occur."
    248 msgid "SUNOS-8000-E8.action"
    249 msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager."
    250 #
    251 # code: SUNOS-8000-FU
    252 # keys: defect.sunos.eft.undiag.fme
    253 #
    254 msgid "SUNOS-8000-FU.type"
    255 msgstr "Defect"
    256 msgid "SUNOS-8000-FU.severity"
    257 msgstr "Major"
    258 msgid "SUNOS-8000-FU.description"
    259 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
    260 msgid "SUNOS-8000-FU.response"
    261 msgstr "Error reports have been logged for examination by Sun."
    262 msgid "SUNOS-8000-FU.impact"
    263 msgstr "Automated diagnosis and response for these events will not occur."
    264 msgid "SUNOS-8000-FU.action"
    265 msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed."
    266 #
    267 # code: SUNOS-8000-G7
    268 # keys: defect.sunos.eft.undiag.limit
    269 #
    270 msgid "SUNOS-8000-G7.type"
    271 msgstr "Defect"
    272 msgid "SUNOS-8000-G7.severity"
    273 msgstr "Minor"
    274 msgid "SUNOS-8000-G7.description"
    275 msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis.  Refer to %s for more information."
    276 msgid "SUNOS-8000-G7.response"
    277 msgstr "Error reports have been logged for examination by Sun."
    278 msgid "SUNOS-8000-G7.impact"
    279 msgstr "Automated diagnosis and response for these events will not occur."
    280 msgid "SUNOS-8000-G7.action"
    281 msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
    282 #
    283 # code: SUNOS-8000-HV
    284 # keys: defect.sunos.eft.undiag.unknown
    285 #
    286 msgid "SUNOS-8000-HV.type"
    287 msgstr "Defect"
    288 msgid "SUNOS-8000-HV.severity"
    289 msgstr "Minor"
    290 msgid "SUNOS-8000-HV.description"
    291 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
    292 msgid "SUNOS-8000-HV.response"
    293 msgstr "Error reports have been logged for examination by Sun."
    294 msgid "SUNOS-8000-HV.impact"
    295 msgstr "Automated diagnosis and response for these events will not occur."
    296 msgid "SUNOS-8000-HV.action"
    297 msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed."
    298