Home | History | Annotate | Download | only in dicts
      1 #
      2 # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
      3 # Use is subject to license terms.
      4 #
      5 # CDDL HEADER START
      6 #
      7 # The contents of this file are subject to the terms of the
      8 # Common Development and Distribution License (the "License").
      9 # You may not use this file except in compliance with the License.
     10 #
     11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
     12 # or http://www.opensolaris.org/os/licensing.
     13 # See the License for the specific language governing permissions
     14 # and limitations under the License.
     15 #
     16 # When distributing Covered Code, include this CDDL HEADER in each
     17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
     18 # If applicable, add the following below this CDDL HEADER, with the
     19 # fields enclosed by brackets "[]" replaced with your own identifying
     20 # information: Portions Copyright [yyyy] [name of copyright owner]
     21 #
     22 # CDDL HEADER END
     23 #
     24 # DO NOT EDIT -- this file is generated by the Event Registry.
     25 #
     26 #
     27 # code: SUN4V-8000-1S
     28 # keys: fault.cpu.ultraSPARC-T1.ireg
     29 #
     30 msgid "SUN4V-8000-1S.type"
     31 msgstr "Fault"
     32 msgid "SUN4V-8000-1S.severity"
     33 msgstr "Minor"
     34 msgid "SUN4V-8000-1S.description"
     35 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
     36 msgid "SUN4V-8000-1S.response"
     37 msgstr "The fault manager will attempt to remove the affected CPU from service."
     38 msgid "SUN4V-8000-1S.impact"
     39 msgstr "System performance may be affected."
     40 msgid "SUN4V-8000-1S.action"
     41 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
     42 #
     43 # code: SUN4V-8000-2A
     44 # keys: fault.cpu.ultraSPARC-T1.freg
     45 #
     46 msgid "SUN4V-8000-2A.type"
     47 msgstr "Fault"
     48 msgid "SUN4V-8000-2A.severity"
     49 msgstr "Major"
     50 msgid "SUN4V-8000-2A.description"
     51 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
     52 msgid "SUN4V-8000-2A.response"
     53 msgstr "None"
     54 msgid "SUN4V-8000-2A.impact"
     55 msgstr "System performance may be affected."
     56 msgid "SUN4V-8000-2A.action"
     57 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
     58 #
     59 # code: SUN4V-8000-3P
     60 # keys: fault.cpu.ultraSPARC-T1.itlb
     61 #
     62 msgid "SUN4V-8000-3P.type"
     63 msgstr "Fault"
     64 msgid "SUN4V-8000-3P.severity"
     65 msgstr "Minor"
     66 msgid "SUN4V-8000-3P.description"
     67 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
     68 msgid "SUN4V-8000-3P.response"
     69 msgstr "The fault manager will attempt to remove the affected CPU from service."
     70 msgid "SUN4V-8000-3P.impact"
     71 msgstr "System performance may be affected.\n"
     72 msgid "SUN4V-8000-3P.action"
     73 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
     74 #
     75 # code: SUN4V-8000-4D
     76 # keys: fault.cpu.ultraSPARC-T1.dtlb
     77 #
     78 msgid "SUN4V-8000-4D.type"
     79 msgstr "Fault"
     80 msgid "SUN4V-8000-4D.severity"
     81 msgstr "Minor"
     82 msgid "SUN4V-8000-4D.description"
     83 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
     84 msgid "SUN4V-8000-4D.response"
     85 msgstr "The fault manager will attempt to remove the affected CPU from service."
     86 msgid "SUN4V-8000-4D.impact"
     87 msgstr "System performance may be affected.\n"
     88 msgid "SUN4V-8000-4D.action"
     89 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
     90 #
     91 # code: SUN4V-8000-5H
     92 # keys: fault.cpu.ultraSPARC-T1.icache
     93 #
     94 msgid "SUN4V-8000-5H.type"
     95 msgstr "Fault"
     96 msgid "SUN4V-8000-5H.severity"
     97 msgstr "Minor"
     98 msgid "SUN4V-8000-5H.description"
     99 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
    100 msgid "SUN4V-8000-5H.response"
    101 msgstr "The fault manager will attempt to remove the affected CPU from service."
    102 msgid "SUN4V-8000-5H.impact"
    103 msgstr "System performance may be affected.\n"
    104 msgid "SUN4V-8000-5H.action"
    105 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
    106 #
    107 # code: SUN4V-8000-63
    108 # keys: fault.cpu.ultraSPARC-T1.dcache
    109 #
    110 msgid "SUN4V-8000-63.type"
    111 msgstr "Fault"
    112 msgid "SUN4V-8000-63.severity"
    113 msgstr "Minor"
    114 msgid "SUN4V-8000-63.description"
    115 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
    116 msgid "SUN4V-8000-63.response"
    117 msgstr "The fault manager will attempt to remove the affected CPU from service."
    118 msgid "SUN4V-8000-63.impact"
    119 msgstr "System performance may be affected.\n"
    120 msgid "SUN4V-8000-63.action"
    121 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
    122 #
    123 # code: SUN4V-8000-7Y
    124 # keys: fault.cpu.ultraSPARC-T1.mau
    125 #
    126 msgid "SUN4V-8000-7Y.type"
    127 msgstr "Fault"
    128 msgid "SUN4V-8000-7Y.severity"
    129 msgstr "Major"
    130 msgid "SUN4V-8000-7Y.description"
    131 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
    132 msgid "SUN4V-8000-7Y.response"
    133 msgstr "None"
    134 msgid "SUN4V-8000-7Y.impact"
    135 msgstr "System performance may be affected.\n"
    136 msgid "SUN4V-8000-7Y.action"
    137 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
    138 #
    139 # code: SUN4V-8000-8Q
    140 # keys: fault.cpu.ultraSPARC-T1.l2cachedata
    141 #
    142 msgid "SUN4V-8000-8Q.type"
    143 msgstr "Fault"
    144 msgid "SUN4V-8000-8Q.severity"
    145 msgstr "Critical"
    146 msgid "SUN4V-8000-8Q.description"
    147 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
    148 msgid "SUN4V-8000-8Q.response"
    149 msgstr "None"
    150 msgid "SUN4V-8000-8Q.impact"
    151 msgstr "System performance may be affected.\n"
    152 msgid "SUN4V-8000-8Q.action"
    153 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
    154 #
    155 # code: SUN4V-8000-9C
    156 # keys: fault.cpu.ultraSPARC-T1.l2cachetag
    157 #
    158 msgid "SUN4V-8000-9C.type"
    159 msgstr "Fault"
    160 msgid "SUN4V-8000-9C.severity"
    161 msgstr "Critical"
    162 msgid "SUN4V-8000-9C.description"
    163 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
    164 msgid "SUN4V-8000-9C.response"
    165 msgstr "None"
    166 msgid "SUN4V-8000-9C.impact"
    167 msgstr "System performance may be affected.\n"
    168 msgid "SUN4V-8000-9C.action"
    169 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
    170 #
    171 # code: SUN4V-8000-AR
    172 # keys: fault.cpu.ultraSPARC-T1.l2cachectl
    173 #
    174 msgid "SUN4V-8000-AR.type"
    175 msgstr "Fault"
    176 msgid "SUN4V-8000-AR.severity"
    177 msgstr "Critical"
    178 msgid "SUN4V-8000-AR.description"
    179 msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
    180 msgid "SUN4V-8000-AR.response"
    181 msgstr "None"
    182 msgid "SUN4V-8000-AR.impact"
    183 msgstr "System performance may be affected.\n"
    184 msgid "SUN4V-8000-AR.action"
    185 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
    186 #
    187 # code: SUN4V-8000-C4
    188 # keys: fault.memory.page
    189 #
    190 msgid "SUN4V-8000-C4.type"
    191 msgstr "Fault"
    192 msgid "SUN4V-8000-C4.severity"
    193 msgstr "Minor"
    194 msgid "SUN4V-8000-C4.description"
    195 msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
    196 msgid "SUN4V-8000-C4.response"
    197 msgstr "An attempt will be made to remove this memory page from service."
    198 msgid "SUN4V-8000-C4.impact"
    199 msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
    200 msgid "SUN4V-8000-C4.action"
    201 msgstr "No repair action is recommended at this time."
    202 #
    203 # code: SUN4V-8000-DX
    204 # keys: fault.memory.dimm
    205 #
    206 msgid "SUN4V-8000-DX.type"
    207 msgstr "Fault"
    208 msgid "SUN4V-8000-DX.severity"
    209 msgstr "Major"
    210 msgid "SUN4V-8000-DX.description"
    211 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
    212 msgid "SUN4V-8000-DX.response"
    213 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
    214 msgid "SUN4V-8000-DX.impact"
    215 msgstr "Total system memory capacity has been reduced."
    216 msgid "SUN4V-8000-DX.action"
    217 msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
    218 #
    219 # code: SUN4V-8000-E2
    220 # keys: fault.memory.bank
    221 #
    222 msgid "SUN4V-8000-E2.type"
    223 msgstr "Fault"
    224 msgid "SUN4V-8000-E2.severity"
    225 msgstr "Critical"
    226 msgid "SUN4V-8000-E2.description"
    227 msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
    228 msgid "SUN4V-8000-E2.response"
    229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
    230 msgid "SUN4V-8000-E2.impact"
    231 msgstr "Total system memory capacity will be reduced as pages are retired."
    232 msgid "SUN4V-8000-E2.action"
    233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
    234 #
    235 # code: SUN4V-8000-FJ
    236 # keys: fault.memory.link-c
    237 #
    238 msgid "SUN4V-8000-FJ.type"
    239 msgstr "Fault"
    240 msgid "SUN4V-8000-FJ.severity"
    241 msgstr "Major"
    242 msgid "SUN4V-8000-FJ.description"
    243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
    244 msgid "SUN4V-8000-FJ.response"
    245 msgstr "No automated response.\n"
    246 msgid "SUN4V-8000-FJ.impact"
    247 msgstr "System performance may be impacted.\n"
    248 msgid "SUN4V-8000-FJ.action"
    249 msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
    250 #
    251 # code: SUN4V-8000-GE
    252 # keys: fault.cpu.ultraSPARC-T2.ireg
    253 #
    254 msgid "SUN4V-8000-GE.type"
    255 msgstr "Fault"
    256 msgid "SUN4V-8000-GE.severity"
    257 msgstr "Minor"
    258 msgid "SUN4V-8000-GE.description"
    259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    260 msgid "SUN4V-8000-GE.response"
    261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
    262 msgid "SUN4V-8000-GE.impact"
    263 msgstr "System performance may be affected. \n"
    264 msgid "SUN4V-8000-GE.action"
    265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    266 #
    267 # code: SUN4V-8000-HP
    268 # keys: fault.cpu.ultraSPARC-T2.freg
    269 #
    270 msgid "SUN4V-8000-HP.type"
    271 msgstr "Fault"
    272 msgid "SUN4V-8000-HP.severity"
    273 msgstr "Minor"
    274 msgid "SUN4V-8000-HP.description"
    275 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    276 msgid "SUN4V-8000-HP.response"
    277 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
    278 msgid "SUN4V-8000-HP.impact"
    279 msgstr "System performance may be affected. \n"
    280 msgid "SUN4V-8000-HP.action"
    281 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    282 #
    283 # code: SUN4V-8000-JA
    284 # keys: fault.cpu.ultraSPARC-T2.misc_reg
    285 #
    286 msgid "SUN4V-8000-JA.type"
    287 msgstr "Fault"
    288 msgid "SUN4V-8000-JA.severity"
    289 msgstr "Minor"
    290 msgid "SUN4V-8000-JA.description"
    291 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    292 msgid "SUN4V-8000-JA.response"
    293 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
    294 msgid "SUN4V-8000-JA.impact"
    295 msgstr "System performance may be affected. \n"
    296 msgid "SUN4V-8000-JA.action"
    297 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    298 #
    299 # code: SUN4V-8000-KS
    300 # keys: fault.cpu.ultraSPARC-T2.itlb
    301 #
    302 msgid "SUN4V-8000-KS.type"
    303 msgstr "Fault"
    304 msgid "SUN4V-8000-KS.severity"
    305 msgstr "Major"
    306 msgid "SUN4V-8000-KS.description"
    307 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    308 msgid "SUN4V-8000-KS.response"
    309 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    310 msgid "SUN4V-8000-KS.impact"
    311 msgstr "System performance is likely to be affected. \n"
    312 msgid "SUN4V-8000-KS.action"
    313 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    314 #
    315 # code: SUN4V-8000-L5
    316 # keys: fault.cpu.ultraSPARC-T2.dtlb
    317 #
    318 msgid "SUN4V-8000-L5.type"
    319 msgstr "Fault"
    320 msgid "SUN4V-8000-L5.severity"
    321 msgstr "Major"
    322 msgid "SUN4V-8000-L5.description"
    323 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    324 msgid "SUN4V-8000-L5.response"
    325 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    326 msgid "SUN4V-8000-L5.impact"
    327 msgstr "System performance is likely to be affected. \n"
    328 msgid "SUN4V-8000-L5.action"
    329 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    330 #
    331 # code: SUN4V-8000-MY
    332 # keys: fault.cpu.ultraSPARC-T2.icache
    333 #
    334 msgid "SUN4V-8000-MY.type"
    335 msgstr "Fault"
    336 msgid "SUN4V-8000-MY.severity"
    337 msgstr "Major"
    338 msgid "SUN4V-8000-MY.description"
    339 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    340 msgid "SUN4V-8000-MY.response"
    341 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    342 msgid "SUN4V-8000-MY.impact"
    343 msgstr "System performance is likely to be affected. \n"
    344 msgid "SUN4V-8000-MY.action"
    345 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    346 #
    347 # code: SUN4V-8000-N3
    348 # keys: fault.cpu.ultraSPARC-T2.dcache
    349 #
    350 msgid "SUN4V-8000-N3.type"
    351 msgstr "Fault"
    352 msgid "SUN4V-8000-N3.severity"
    353 msgstr "Major"
    354 msgid "SUN4V-8000-N3.description"
    355 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    356 msgid "SUN4V-8000-N3.response"
    357 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    358 msgid "SUN4V-8000-N3.impact"
    359 msgstr "System performance is likely to be affected. \n"
    360 msgid "SUN4V-8000-N3.action"
    361 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    362 #
    363 # code: SUN4V-8000-PH
    364 # keys: fault.cpu.ultraSPARC-T2.mau
    365 #
    366 msgid "SUN4V-8000-PH.type"
    367 msgstr "Fault"
    368 msgid "SUN4V-8000-PH.severity"
    369 msgstr "Major"
    370 msgid "SUN4V-8000-PH.description"
    371 msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n  Refer to %s for more information."
    372 msgid "SUN4V-8000-PH.response"
    373 msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
    374 msgid "SUN4V-8000-PH.impact"
    375 msgstr "System performance is likely to be affected. \n"
    376 msgid "SUN4V-8000-PH.action"
    377 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    378 #
    379 # code: SUN4V-8000-QD
    380 # keys: fault.cpu.ultraSPARC-T2.l2data-c
    381 #
    382 msgid "SUN4V-8000-QD.type"
    383 msgstr "Fault"
    384 msgid "SUN4V-8000-QD.severity"
    385 msgstr "Critical"
    386 msgid "SUN4V-8000-QD.description"
    387 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
    388 msgid "SUN4V-8000-QD.response"
    389 msgstr "No automated response.\n"
    390 msgid "SUN4V-8000-QD.impact"
    391 msgstr "System performance is likely to be affected. \n"
    392 msgid "SUN4V-8000-QD.action"
    393 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    394 #
    395 # code: SUN4V-8000-R4
    396 # keys: fault.cpu.ultraSPARC-T2.l2cachetag
    397 #
    398 msgid "SUN4V-8000-R4.type"
    399 msgstr "Fault"
    400 msgid "SUN4V-8000-R4.severity"
    401 msgstr "Critical"
    402 msgid "SUN4V-8000-R4.description"
    403 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
    404 msgid "SUN4V-8000-R4.response"
    405 msgstr "No automated response.\n"
    406 msgid "SUN4V-8000-R4.impact"
    407 msgstr "System performance is likely to be affected. \n"
    408 msgid "SUN4V-8000-R4.action"
    409 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    410 #
    411 # code: SUN4V-8000-SR
    412 # keys: fault.cpu.ultraSPARC-T2.l2cachectl
    413 #
    414 msgid "SUN4V-8000-SR.type"
    415 msgstr "Fault"
    416 msgid "SUN4V-8000-SR.severity"
    417 msgstr "Critical"
    418 msgid "SUN4V-8000-SR.description"
    419 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
    420 msgid "SUN4V-8000-SR.response"
    421 msgstr "No automated response.\n"
    422 msgid "SUN4V-8000-SR.impact"
    423 msgstr "System performance is likely to be affected. System may be unstable.\n"
    424 msgid "SUN4V-8000-SR.action"
    425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    426 #
    427 # code: SUN4V-8000-TC
    428 # keys: fault.memory.link-u
    429 #
    430 msgid "SUN4V-8000-TC.type"
    431 msgstr "Fault"
    432 msgid "SUN4V-8000-TC.severity"
    433 msgstr "Critical"
    434 msgid "SUN4V-8000-TC.description"
    435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
    436 msgid "SUN4V-8000-TC.response"
    437 msgstr "No automated response.\n"
    438 msgid "SUN4V-8000-TC.impact"
    439 msgstr "System performance may be impacted.\n"
    440 msgid "SUN4V-8000-TC.action"
    441 msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
    442 #
    443 # code: SUN4V-8000-UQ
    444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
    445 #
    446 msgid "SUN4V-8000-UQ.type"
    447 msgstr "Fault"
    448 msgid "SUN4V-8000-UQ.severity"
    449 msgstr "Critical"
    450 msgid "SUN4V-8000-UQ.description"
    451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
    452 msgid "SUN4V-8000-UQ.response"
    453 msgstr "No automated response.\n"
    454 msgid "SUN4V-8000-UQ.impact"
    455 msgstr "System performance is likely to be affected. \n"
    456 msgid "SUN4V-8000-UQ.action"
    457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    458 #
    459 # code: SUN4V-8000-VE
    460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
    461 #
    462 msgid "SUN4V-8000-VE.type"
    463 msgstr "Fault"
    464 msgid "SUN4V-8000-VE.severity"
    465 msgstr "Critical"
    466 msgid "SUN4V-8000-VE.description"
    467 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
    468 msgid "SUN4V-8000-VE.response"
    469 msgstr "No automated response.\n"
    470 msgid "SUN4V-8000-VE.impact"
    471 msgstr "System performance is likely to be affected. \n"
    472 msgid "SUN4V-8000-VE.action"
    473 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    474 #
    475 # code: SUN4V-8000-WJ
    476 # keys: fault.cpu.ultraSPARC-T1.l2data-u
    477 #
    478 msgid "SUN4V-8000-WJ.type"
    479 msgstr "Fault"
    480 msgid "SUN4V-8000-WJ.severity"
    481 msgstr "Critical"
    482 msgid "SUN4V-8000-WJ.description"
    483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
    484 msgid "SUN4V-8000-WJ.response"
    485 msgstr "No automated response.\n"
    486 msgid "SUN4V-8000-WJ.impact"
    487 msgstr "System performance is likely to be affected. \n"
    488 msgid "SUN4V-8000-WJ.action"
    489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    490 #
    491 # code: SUN4V-8000-X2
    492 # keys: fault.memory.datapath
    493 #
    494 msgid "SUN4V-8000-X2.type"
    495 msgstr "Fault"
    496 msgid "SUN4V-8000-X2.severity"
    497 msgstr "Major"
    498 msgid "SUN4V-8000-X2.description"
    499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
    500 msgid "SUN4V-8000-X2.response"
    501 msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
    502 msgid "SUN4V-8000-X2.impact"
    503 msgstr "System performance and stability may be affected. \n"
    504 msgid "SUN4V-8000-X2.action"
    505 msgstr "Contact your service provider for further diagnosis.\n"
    506 #
    507 # code: SUN4V-8000-YX
    508 # keys: fault.io.n2.ncu
    509 #
    510 msgid "SUN4V-8000-YX.type"
    511 msgstr "Fault"
    512 msgid "SUN4V-8000-YX.severity"
    513 msgstr "Critical"
    514 msgid "SUN4V-8000-YX.description"
    515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
    516 msgid "SUN4V-8000-YX.response"
    517 msgstr "One or more device instances may be disabled\n"
    518 msgid "SUN4V-8000-YX.impact"
    519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    520 msgid "SUN4V-8000-YX.action"
    521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    522 #
    523 # code: SUN4V-8001-02
    524 # keys: fault.io.n2.dmu
    525 #
    526 msgid "SUN4V-8001-02.type"
    527 msgstr "Fault"
    528 msgid "SUN4V-8001-02.severity"
    529 msgstr "Critical"
    530 msgid "SUN4V-8001-02.description"
    531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
    532 msgid "SUN4V-8001-02.response"
    533 msgstr "One or more device instances may be disabled\n"
    534 msgid "SUN4V-8001-02.impact"
    535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    536 msgid "SUN4V-8001-02.action"
    537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    538 #
    539 # code: SUN4V-8001-1X
    540 # keys: fault.io.n2.niu
    541 #
    542 msgid "SUN4V-8001-1X.type"
    543 msgstr "Fault"
    544 msgid "SUN4V-8001-1X.severity"
    545 msgstr "Critical"
    546 msgid "SUN4V-8001-1X.description"
    547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
    548 msgid "SUN4V-8001-1X.response"
    549 msgstr "One or more device instances may be disabled\n"
    550 msgid "SUN4V-8001-1X.impact"
    551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    552 msgid "SUN4V-8001-1X.action"
    553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    554 #
    555 # code: SUN4V-8001-2E
    556 # keys: fault.io.n2.siu
    557 #
    558 msgid "SUN4V-8001-2E.type"
    559 msgstr "Fault"
    560 msgid "SUN4V-8001-2E.severity"
    561 msgstr "Critical"
    562 msgid "SUN4V-8001-2E.description"
    563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
    564 msgid "SUN4V-8001-2E.response"
    565 msgstr "One or more device instances may be disabled\n"
    566 msgid "SUN4V-8001-2E.impact"
    567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    568 msgid "SUN4V-8001-2E.action"
    569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    570 #
    571 # code: SUN4V-8001-3J
    572 # keys: fault.io.n2.soc
    573 #
    574 msgid "SUN4V-8001-3J.type"
    575 msgstr "Fault"
    576 msgid "SUN4V-8001-3J.severity"
    577 msgstr "Critical"
    578 msgid "SUN4V-8001-3J.description"
    579 msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
    580 msgid "SUN4V-8001-3J.response"
    581 msgstr "One or more device instances may be disabled\n"
    582 msgid "SUN4V-8001-3J.impact"
    583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    584 msgid "SUN4V-8001-3J.action"
    585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    586 #
    587 # code: SUN4V-8001-4C
    588 # keys: fault.io.n2.crossbar
    589 #
    590 msgid "SUN4V-8001-4C.type"
    591 msgstr "Fault"
    592 msgid "SUN4V-8001-4C.severity"
    593 msgstr "Critical"
    594 msgid "SUN4V-8001-4C.description"
    595 msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
    596 msgid "SUN4V-8001-4C.response"
    597 msgstr "One or more device instances may be disabled\n"
    598 msgid "SUN4V-8001-4C.impact"
    599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    600 msgid "SUN4V-8001-4C.action"
    601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    602 #
    603 # code: SUN4V-8001-5Q
    604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
    605 #
    606 msgid "SUN4V-8001-5Q.type"
    607 msgstr "Fault"
    608 msgid "SUN4V-8001-5Q.severity"
    609 msgstr "Critical"
    610 msgid "SUN4V-8001-5Q.description"
    611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
    612 msgid "SUN4V-8001-5Q.response"
    613 msgstr "One or more device instances may be disabled\n"
    614 msgid "SUN4V-8001-5Q.impact"
    615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    616 msgid "SUN4V-8001-5Q.action"
    617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    618 #
    619 # code: SUN4V-8001-64
    620 # keys: fault.io.vf.ncx
    621 #
    622 msgid "SUN4V-8001-64.type"
    623 msgstr "Fault"
    624 msgid "SUN4V-8001-64.severity"
    625 msgstr "Critical"
    626 msgid "SUN4V-8001-64.description"
    627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
    628 msgid "SUN4V-8001-64.response"
    629 msgstr "One or more device instances may be disabled\n"
    630 msgid "SUN4V-8001-64.impact"
    631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
    632 msgid "SUN4V-8001-64.action"
    633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
    634 #
    635 # code: SUN4V-8001-7R
    636 # keys: fault.memory.link-f
    637 #
    638 msgid "SUN4V-8001-7R.type"
    639 msgstr "Fault"
    640 msgid "SUN4V-8001-7R.severity"
    641 msgstr "Major"
    642 msgid "SUN4V-8001-7R.description"
    643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
    644 msgid "SUN4V-8001-7R.response"
    645 msgstr "No automated response.\n"
    646 msgid "SUN4V-8001-7R.impact"
    647 msgstr "System performance may be impacted.\n"
    648 msgid "SUN4V-8001-7R.action"
    649 msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
    650 #
    651 # code: SUN4V-8001-8H
    652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
    653 #
    654 msgid "SUN4V-8001-8H.type"
    655 msgstr "Fault"
    656 msgid "SUN4V-8001-8H.severity"
    657 msgstr "Minor"
    658 msgid "SUN4V-8001-8H.description"
    659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    660 msgid "SUN4V-8001-8H.response"
    661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
    662 msgid "SUN4V-8001-8H.impact"
    663 msgstr "System performance may be affected. \n"
    664 msgid "SUN4V-8001-8H.action"
    665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    666 #
    667 # code: SUN4V-8001-9D
    668 # keys: fault.cpu.ultraSPARC-T2plus.freg
    669 #
    670 msgid "SUN4V-8001-9D.type"
    671 msgstr "Fault"
    672 msgid "SUN4V-8001-9D.severity"
    673 msgstr "Minor"
    674 msgid "SUN4V-8001-9D.description"
    675 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    676 msgid "SUN4V-8001-9D.response"
    677 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
    678 msgid "SUN4V-8001-9D.impact"
    679 msgstr "System performance may be affected. \n"
    680 msgid "SUN4V-8001-9D.action"
    681 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    682 #
    683 # code: SUN4V-8001-AY
    684 # keys: fault.cpu.ultraSPARC-T2plus.misc_reg
    685 #
    686 msgid "SUN4V-8001-AY.type"
    687 msgstr "Fault"
    688 msgid "SUN4V-8001-AY.severity"
    689 msgstr "Minor"
    690 msgid "SUN4V-8001-AY.description"
    691 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    692 msgid "SUN4V-8001-AY.response"
    693 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
    694 msgid "SUN4V-8001-AY.impact"
    695 msgstr "System performance may be affected. \n"
    696 msgid "SUN4V-8001-AY.action"
    697 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    698 #
    699 # code: SUN4V-8001-C3
    700 # keys: fault.cpu.ultraSPARC-T2plus.itlb
    701 #
    702 msgid "SUN4V-8001-C3.type"
    703 msgstr "Fault"
    704 msgid "SUN4V-8001-C3.severity"
    705 msgstr "Major"
    706 msgid "SUN4V-8001-C3.description"
    707 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    708 msgid "SUN4V-8001-C3.response"
    709 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    710 msgid "SUN4V-8001-C3.impact"
    711 msgstr "System performance is likely to be affected. \n"
    712 msgid "SUN4V-8001-C3.action"
    713 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    714 #
    715 # code: SUN4V-8001-DS
    716 # keys: fault.cpu.ultraSPARC-T2plus.dtlb
    717 #
    718 msgid "SUN4V-8001-DS.type"
    719 msgstr "Fault"
    720 msgid "SUN4V-8001-DS.severity"
    721 msgstr "Major"
    722 msgid "SUN4V-8001-DS.description"
    723 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    724 msgid "SUN4V-8001-DS.response"
    725 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    726 msgid "SUN4V-8001-DS.impact"
    727 msgstr "System performance is likely to be affected. \n"
    728 msgid "SUN4V-8001-DS.action"
    729 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    730 #
    731 # code: SUN4V-8001-E5
    732 # keys: fault.cpu.ultraSPARC-T2plus.icache
    733 #
    734 msgid "SUN4V-8001-E5.type"
    735 msgstr "Fault"
    736 msgid "SUN4V-8001-E5.severity"
    737 msgstr "Major"
    738 msgid "SUN4V-8001-E5.description"
    739 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    740 msgid "SUN4V-8001-E5.response"
    741 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    742 msgid "SUN4V-8001-E5.impact"
    743 msgstr "System performance is likely to be affected. \n"
    744 msgid "SUN4V-8001-E5.action"
    745 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    746 #
    747 # code: SUN4V-8001-FP
    748 # keys: fault.cpu.ultraSPARC-T2plus.dcache
    749 #
    750 msgid "SUN4V-8001-FP.type"
    751 msgstr "Fault"
    752 msgid "SUN4V-8001-FP.severity"
    753 msgstr "Major"
    754 msgid "SUN4V-8001-FP.description"
    755 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    756 msgid "SUN4V-8001-FP.response"
    757 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
    758 msgid "SUN4V-8001-FP.impact"
    759 msgstr "System performance is likely to be affected. \n"
    760 msgid "SUN4V-8001-FP.action"
    761 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    762 #
    763 # code: SUN4V-8001-GA
    764 # keys: fault.cpu.ultraSPARC-T2plus.mau
    765 #
    766 msgid "SUN4V-8001-GA.type"
    767 msgstr "Fault"
    768 msgid "SUN4V-8001-GA.severity"
    769 msgstr "Major"
    770 msgid "SUN4V-8001-GA.description"
    771 msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
    772 msgid "SUN4V-8001-GA.response"
    773 msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
    774 msgid "SUN4V-8001-GA.impact"
    775 msgstr "System performance is likely to be affected. \n"
    776 msgid "SUN4V-8001-GA.action"
    777 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    778 #
    779 # code: SUN4V-8001-HJ
    780 # keys: fault.cpu.ultraSPARC-T2plus.l2data-c
    781 #
    782 msgid "SUN4V-8001-HJ.type"
    783 msgstr "Fault"
    784 msgid "SUN4V-8001-HJ.severity"
    785 msgstr "Critical"
    786 msgid "SUN4V-8001-HJ.description"
    787 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
    788 msgid "SUN4V-8001-HJ.response"
    789 msgstr "No automated response.\n"
    790 msgid "SUN4V-8001-HJ.impact"
    791 msgstr "System performance is likely to be affected. \n"
    792 msgid "SUN4V-8001-HJ.action"
    793 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    794 #
    795 # code: SUN4V-8001-JE
    796 # keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
    797 #
    798 msgid "SUN4V-8001-JE.type"
    799 msgstr "Fault"
    800 msgid "SUN4V-8001-JE.severity"
    801 msgstr "Critical"
    802 msgid "SUN4V-8001-JE.description"
    803 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
    804 msgid "SUN4V-8001-JE.response"
    805 msgstr "No automated response.\n"
    806 msgid "SUN4V-8001-JE.impact"
    807 msgstr "System performance is likely to be affected. \n"
    808 msgid "SUN4V-8001-JE.action"
    809 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    810 #
    811 # code: SUN4V-8001-KX
    812 # keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
    813 #
    814 msgid "SUN4V-8001-KX.type"
    815 msgstr "Fault"
    816 msgid "SUN4V-8001-KX.severity"
    817 msgstr "Critical"
    818 msgid "SUN4V-8001-KX.description"
    819 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
    820 msgid "SUN4V-8001-KX.response"
    821 msgstr "No automated response.\n"
    822 msgid "SUN4V-8001-KX.impact"
    823 msgstr "System performance is likely to be affected. System may be unstable.\n"
    824 msgid "SUN4V-8001-KX.action"
    825 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    826 #
    827 # code: SUN4V-8001-L2
    828 # keys: fault.cpu.ultraSPARC-T2plus.l2data-u
    829 #
    830 msgid "SUN4V-8001-L2.type"
    831 msgstr "Fault"
    832 msgid "SUN4V-8001-L2.severity"
    833 msgstr "Critical"
    834 msgid "SUN4V-8001-L2.description"
    835 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
    836 msgid "SUN4V-8001-L2.response"
    837 msgstr "No automated response.\n"
    838 msgid "SUN4V-8001-L2.impact"
    839 msgstr "System performance is likely to be affected. \n"
    840 msgid "SUN4V-8001-L2.action"
    841 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    842 #
    843 # code: SUN4V-8001-MR
    844 # keys: fault.cpu.ultraSPARC-T2plus.lfu-f
    845 #
    846 msgid "SUN4V-8001-MR.type"
    847 msgstr "Fault"
    848 msgid "SUN4V-8001-MR.severity"
    849 msgstr "Major"
    850 msgid "SUN4V-8001-MR.description"
    851 msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n  Refer to %s for more information."
    852 msgid "SUN4V-8001-MR.response"
    853 msgstr "No other automated response.\n"
    854 msgid "SUN4V-8001-MR.impact"
    855 msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
    856 msgid "SUN4V-8001-MR.action"
    857 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    858 #
    859 # code: SUN4V-8001-N4
    860 # keys: fault.cpu.ultraSPARC-T2plus.lfu-p
    861 #
    862 msgid "SUN4V-8001-N4.type"
    863 msgstr "Fault"
    864 msgid "SUN4V-8001-N4.severity"
    865 msgstr "Major"
    866 msgid "SUN4V-8001-N4.description"
    867 msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n  Refer to %s for more information."
    868 msgid "SUN4V-8001-N4.response"
    869 msgstr "No automated response.\n"
    870 msgid "SUN4V-8001-N4.impact"
    871 msgstr "The system has most likely taken a fatal reset.\n"
    872 msgid "SUN4V-8001-N4.action"
    873 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    874 #
    875 # code: SUN4V-8001-PQ
    876 # keys: fault.cpu.ultraSPARC-T2plus.lfu-u
    877 #
    878 msgid "SUN4V-8001-PQ.type"
    879 msgstr "Fault"
    880 msgid "SUN4V-8001-PQ.severity"
    881 msgstr "Major"
    882 msgid "SUN4V-8001-PQ.description"
    883 msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n  Refer to %s for more information."
    884 msgid "SUN4V-8001-PQ.response"
    885 msgstr "No automated response.\n"
    886 msgid "SUN4V-8001-PQ.impact"
    887 msgstr "The system's integrity is seriously compromised.\n"
    888 msgid "SUN4V-8001-PQ.action"
    889 msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
    890 #
    891 # code: SUN4V-8001-QC
    892 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
    893 #
    894 msgid "SUN4V-8001-QC.type"
    895 msgstr "Fault"
    896 msgid "SUN4V-8001-QC.severity"
    897 msgstr "Critical"
    898 msgid "SUN4V-8001-QC.description"
    899 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n  Refer to %s for more information."
    900 msgid "SUN4V-8001-QC.response"
    901 msgstr "No automated reponse.\n"
    902 msgid "SUN4V-8001-QC.impact"
    903 msgstr "The system's integrity is compromised.\n"
    904 msgid "SUN4V-8001-QC.action"
    905 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
    906 #
    907 # code: SUN4V-8001-R3
    908 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
    909 #
    910 msgid "SUN4V-8001-R3.type"
    911 msgstr "Fault"
    912 msgid "SUN4V-8001-R3.severity"
    913 msgstr "Major"
    914 msgid "SUN4V-8001-R3.description"
    915 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n  Refer to %s for more information."
    916 msgid "SUN4V-8001-R3.response"
    917 msgstr "No automated reponse.\n"
    918 msgid "SUN4V-8001-R3.impact"
    919 msgstr "The system's integrity is compromised.\n"
    920 msgid "SUN4V-8001-R3.action"
    921 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
    922 #
    923 # code: SUN4V-8001-SY
    924 # keys: fault.cpu.ultraSPARC-T2plus.chip
    925 #
    926 msgid "SUN4V-8001-SY.type"
    927 msgstr "Fault"
    928 msgid "SUN4V-8001-SY.severity"
    929 msgstr "Critical"
    930 msgid "SUN4V-8001-SY.description"
    931 msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n  Refer to %s for more information."
    932 msgid "SUN4V-8001-SY.response"
    933 msgstr "No automated reponse.\n"
    934 msgid "SUN4V-8001-SY.impact"
    935 msgstr "The system's integrity is seriously compromised.\n"
    936 msgid "SUN4V-8001-SY.action"
    937 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
    938 #
    939 # code: SUN4V-8001-TD
    940 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
    941 #
    942 msgid "SUN4V-8001-TD.type"
    943 msgstr "Fault"
    944 msgid "SUN4V-8001-TD.severity"
    945 msgstr "Minor"
    946 msgid "SUN4V-8001-TD.description"
    947 msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n  Refer to %s for more information."
    948 msgid "SUN4V-8001-TD.response"
    949 msgstr "No automated reponse.\n"
    950 msgid "SUN4V-8001-TD.impact"
    951 msgstr "The system's integrity is seriously compromised.\n"
    952 msgid "SUN4V-8001-TD.action"
    953 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
    954 #
    955 # code: SUN4V-8001-UH
    956 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
    957 #
    958 msgid "SUN4V-8001-UH.type"
    959 msgstr "Fault"
    960 msgid "SUN4V-8001-UH.severity"
    961 msgstr "Major"
    962 msgid "SUN4V-8001-UH.description"
    963 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n  Refer to %s for more information."
    964 msgid "SUN4V-8001-UH.response"
    965 msgstr "No automated reponse.\n"
    966 msgid "SUN4V-8001-UH.impact"
    967 msgstr "The system's performance may be impacted.\n"
    968 msgid "SUN4V-8001-UH.action"
    969 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
    970 #
    971 # code: SUN4V-8001-VA
    972 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
    973 #
    974 msgid "SUN4V-8001-VA.type"
    975 msgstr "Fault"
    976 msgid "SUN4V-8001-VA.severity"
    977 msgstr "Critical"
    978 msgid "SUN4V-8001-VA.description"
    979 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n  Refer to %s for more information."
    980 msgid "SUN4V-8001-VA.response"
    981 msgstr "No automated reponse.\n"
    982 msgid "SUN4V-8001-VA.impact"
    983 msgstr "The system's integrity is seriously compromised.\n"
    984 msgid "SUN4V-8001-VA.action"
    985 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
    986 #
    987 # code: SUN4V-8001-WP
    988 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
    989 #
    990 msgid "SUN4V-8001-WP.type"
    991 msgstr "Fault"
    992 msgid "SUN4V-8001-WP.severity"
    993 msgstr "Critical"
    994 msgid "SUN4V-8001-WP.description"
    995 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n  Refer to %s for more information."
    996 msgid "SUN4V-8001-WP.response"
    997 msgstr "No automated reponse.\n"
    998 msgid "SUN4V-8001-WP.impact"
    999 msgstr "The system's integrity is seriously compromised.\n"
   1000 msgid "SUN4V-8001-WP.action"
   1001 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
   1002 #
   1003 # code: SUN4V-8001-X5
   1004 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
   1005 #
   1006 msgid "SUN4V-8001-X5.type"
   1007 msgstr "Fault"
   1008 msgid "SUN4V-8001-X5.severity"
   1009 msgstr "Critical"
   1010 msgid "SUN4V-8001-X5.description"
   1011 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n  Refer to %s for more information."
   1012 msgid "SUN4V-8001-X5.response"
   1013 msgstr "No automated reponse.\n"
   1014 msgid "SUN4V-8001-X5.impact"
   1015 msgstr "The system's performance may be compromised.\n"
   1016 msgid "SUN4V-8001-X5.action"
   1017 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
   1018 #
   1019 # code: SUN4V-8001-YS
   1020 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
   1021 #
   1022 msgid "SUN4V-8001-YS.type"
   1023 msgstr "Fault"
   1024 msgid "SUN4V-8001-YS.severity"
   1025 msgstr "Major"
   1026 msgid "SUN4V-8001-YS.description"
   1027 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n  Refer to %s for more information."
   1028 msgid "SUN4V-8001-YS.response"
   1029 msgstr "No automated reponse.\n"
   1030 msgid "SUN4V-8001-YS.impact"
   1031 msgstr "The system's integrity may be seriously compromised.\n"
   1032 msgid "SUN4V-8001-YS.action"
   1033 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
   1034 #
   1035 # code: SUN4V-8002-0C
   1036 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
   1037 #
   1038 msgid "SUN4V-8002-0C.type"
   1039 msgstr "Fault"
   1040 msgid "SUN4V-8002-0C.severity"
   1041 msgstr "Major"
   1042 msgid "SUN4V-8002-0C.description"
   1043 msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n  Refer to %s for more information."
   1044 msgid "SUN4V-8002-0C.response"
   1045 msgstr "No automated reponse.\n"
   1046 msgid "SUN4V-8002-0C.impact"
   1047 msgstr "The system's performance may be impacted.\n"
   1048 msgid "SUN4V-8002-0C.action"
   1049 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
   1050 #
   1051 # code: SUN4V-8002-1Q
   1052 # keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
   1053 #
   1054 msgid "SUN4V-8002-1Q.type"
   1055 msgstr "Fault"
   1056 msgid "SUN4V-8002-1Q.severity"
   1057 msgstr "Major"
   1058 msgid "SUN4V-8002-1Q.description"
   1059 msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n  Refer to %s for more information."
   1060 msgid "SUN4V-8002-1Q.response"
   1061 msgstr "No automated reponse.\n"
   1062 msgid "SUN4V-8002-1Q.impact"
   1063 msgstr "The system's performance may be impacted.\n"
   1064 msgid "SUN4V-8002-1Q.action"
   1065 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
   1066 #
   1067 # code: SUN4V-8002-24
   1068 # keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
   1069 #
   1070 msgid "SUN4V-8002-24.type"
   1071 msgstr "Fault"
   1072 msgid "SUN4V-8002-24.severity"
   1073 msgstr "Critical"
   1074 msgid "SUN4V-8002-24.description"
   1075 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n  Refer to %s for more information."
   1076 msgid "SUN4V-8002-24.response"
   1077 msgstr "No automated reponse.\n"
   1078 msgid "SUN4V-8002-24.impact"
   1079 msgstr "The system's integrity is seriously compromised.\n"
   1080 msgid "SUN4V-8002-24.action"
   1081 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
   1082 #
   1083 # code: SUN4V-8002-3R
   1084 # keys: fault.memory.dimm-page-retires-excessive
   1085 #
   1086 msgid "SUN4V-8002-3R.type"
   1087 msgstr "Fault"
   1088 msgid "SUN4V-8002-3R.severity"
   1089 msgstr "Major"
   1090 msgid "SUN4V-8002-3R.description"
   1091 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n  Refer to %s for more information."
   1092 msgid "SUN4V-8002-3R.response"
   1093 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
   1094 msgid "SUN4V-8002-3R.impact"
   1095 msgstr "Total system memory capacity has been reduced.\n"
   1096 msgid "SUN4V-8002-3R.action"
   1097 msgstr "Schedule a repair procedure to replace the DIMM.  Use fmadm faulty to identify the DIMM to replace.\n"
   1098 #
   1099 # code: SUN4V-8002-42
   1100 # keys: fault.memory.dimm-ue-imminent
   1101 #
   1102 msgid "SUN4V-8002-42.type"
   1103 msgstr "Fault"
   1104 msgid "SUN4V-8002-42.severity"
   1105 msgstr "Critical"
   1106 msgid "SUN4V-8002-42.description"
   1107 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
   1108 msgid "SUN4V-8002-42.response"
   1109 msgstr "None at this time.\n"
   1110 msgid "SUN4V-8002-42.impact"
   1111 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
   1112 msgid "SUN4V-8002-42.action"
   1113 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
   1114 #
   1115 # code: SUN4V-8002-5X
   1116 # keys: fault.memory.dram-ue-imminent
   1117 #
   1118 msgid "SUN4V-8002-5X.type"
   1119 msgstr "Fault"
   1120 msgid "SUN4V-8002-5X.severity"
   1121 msgstr "Critical"
   1122 msgid "SUN4V-8002-5X.description"
   1123 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
   1124 msgid "SUN4V-8002-5X.response"
   1125 msgstr "None at this time.\n"
   1126 msgid "SUN4V-8002-5X.impact"
   1127 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
   1128 msgid "SUN4V-8002-5X.action"
   1129 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
   1130 #
   1131 # code: SUN4V-8002-6E
   1132 # keys: fault.cpu.generic-sparc.strand
   1133 #
   1134 msgid "SUN4V-8002-6E.type"
   1135 msgstr "Fault"
   1136 msgid "SUN4V-8002-6E.severity"
   1137 msgstr "Major"
   1138 msgid "SUN4V-8002-6E.description"
   1139 msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n  Refer to %s for more information."
   1140 msgid "SUN4V-8002-6E.response"
   1141 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
   1142 msgid "SUN4V-8002-6E.impact"
   1143 msgstr "System performance may be affected. \n"
   1144 msgid "SUN4V-8002-6E.action"
   1145 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1146 #
   1147 # code: SUN4V-8002-7J
   1148 # keys: fault.cpu.generic-sparc.strand-nr
   1149 #
   1150 msgid "SUN4V-8002-7J.type"
   1151 msgstr "Fault"
   1152 msgid "SUN4V-8002-7J.severity"
   1153 msgstr "Major"
   1154 msgid "SUN4V-8002-7J.description"
   1155 msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n  Refer to %s for more information."
   1156 msgid "SUN4V-8002-7J.response"
   1157 msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n"
   1158 msgid "SUN4V-8002-7J.impact"
   1159 msgstr "System performance may be affected. \n"
   1160 msgid "SUN4V-8002-7J.action"
   1161 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1162 #
   1163 # code: SUN4V-8002-8S
   1164 # keys: fault.cpu.generic-sparc.strand-uc
   1165 #
   1166 msgid "SUN4V-8002-8S.type"
   1167 msgstr "Fault"
   1168 msgid "SUN4V-8002-8S.severity"
   1169 msgstr "Critical"
   1170 msgid "SUN4V-8002-8S.description"
   1171 msgstr "This strand has encountered an uncorrectable error.\n  Refer to %s for more information."
   1172 msgid "SUN4V-8002-8S.response"
   1173 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
   1174 msgid "SUN4V-8002-8S.impact"
   1175 msgstr "System performance may be affected. \n"
   1176 msgid "SUN4V-8002-8S.action"
   1177 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1178 #
   1179 # code: SUN4V-8002-95
   1180 # keys: fault.cpu.generic-sparc.strand-uc-nr
   1181 #
   1182 msgid "SUN4V-8002-95.type"
   1183 msgstr "Fault"
   1184 msgid "SUN4V-8002-95.severity"
   1185 msgstr "Critical"
   1186 msgid "SUN4V-8002-95.description"
   1187 msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n  Refer to %s for more information."
   1188 msgid "SUN4V-8002-95.response"
   1189 msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n"
   1190 msgid "SUN4V-8002-95.impact"
   1191 msgstr "System performance may be affected. \n"
   1192 msgid "SUN4V-8002-95.action"
   1193 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1194 #
   1195 # code: SUN4V-8002-AP
   1196 # keys: fault.cpu.generic-sparc.core
   1197 #
   1198 msgid "SUN4V-8002-AP.type"
   1199 msgstr "Fault"
   1200 msgid "SUN4V-8002-AP.severity"
   1201 msgstr "Major"
   1202 msgid "SUN4V-8002-AP.description"
   1203 msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n  Refer to %s for more information."
   1204 msgid "SUN4V-8002-AP.response"
   1205 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
   1206 msgid "SUN4V-8002-AP.impact"
   1207 msgstr "System performance may be affected. \n"
   1208 msgid "SUN4V-8002-AP.action"
   1209 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1210 #
   1211 # code: SUN4V-8002-CA
   1212 # keys: fault.cpu.generic-sparc.core-nr
   1213 #
   1214 msgid "SUN4V-8002-CA.type"
   1215 msgstr "Fault"
   1216 msgid "SUN4V-8002-CA.severity"
   1217 msgstr "Major"
   1218 msgid "SUN4V-8002-CA.description"
   1219 msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n  Refer to %s for more information."
   1220 msgid "SUN4V-8002-CA.response"
   1221 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
   1222 msgid "SUN4V-8002-CA.impact"
   1223 msgstr "System performance may be affected. \n"
   1224 msgid "SUN4V-8002-CA.action"
   1225 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1226 #
   1227 # code: SUN4V-8002-DH
   1228 # keys: fault.cpu.generic-sparc.core-uc
   1229 #
   1230 msgid "SUN4V-8002-DH.type"
   1231 msgstr "Fault"
   1232 msgid "SUN4V-8002-DH.severity"
   1233 msgstr "Critical"
   1234 msgid "SUN4V-8002-DH.description"
   1235 msgstr "This core has encountered an uncorrectable error.\n  Refer to %s for more information."
   1236 msgid "SUN4V-8002-DH.response"
   1237 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
   1238 msgid "SUN4V-8002-DH.impact"
   1239 msgstr "System performance may be affected. \n"
   1240 msgid "SUN4V-8002-DH.action"
   1241 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1242 #
   1243 # code: SUN4V-8002-ED
   1244 # keys: fault.cpu.generic-sparc.core-uc-nr
   1245 #
   1246 msgid "SUN4V-8002-ED.type"
   1247 msgstr "Fault"
   1248 msgid "SUN4V-8002-ED.severity"
   1249 msgstr "Critical"
   1250 msgid "SUN4V-8002-ED.description"
   1251 msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n  Refer to %s for more information."
   1252 msgid "SUN4V-8002-ED.response"
   1253 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
   1254 msgid "SUN4V-8002-ED.impact"
   1255 msgstr "System performance may be affected. \n"
   1256 msgid "SUN4V-8002-ED.action"
   1257 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1258 #
   1259 # code: SUN4V-8002-FY
   1260 # keys: fault.cpu.generic-sparc.chip
   1261 #
   1262 msgid "SUN4V-8002-FY.type"
   1263 msgstr "Fault"
   1264 msgid "SUN4V-8002-FY.severity"
   1265 msgstr "Critical"
   1266 msgid "SUN4V-8002-FY.description"
   1267 msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n  Refer to %s for more information."
   1268 msgid "SUN4V-8002-FY.response"
   1269 msgstr "No automated response.\n"
   1270 msgid "SUN4V-8002-FY.impact"
   1271 msgstr "System performance may be affected. \n"
   1272 msgid "SUN4V-8002-FY.action"
   1273 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1274 #
   1275 # code: SUN4V-8002-G3
   1276 # keys: fault.cpu.generic-sparc.chip-nr
   1277 #
   1278 msgid "SUN4V-8002-G3.type"
   1279 msgstr "Fault"
   1280 msgid "SUN4V-8002-G3.severity"
   1281 msgstr "Critical"
   1282 msgid "SUN4V-8002-G3.description"
   1283 msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n  Refer to %s for more information."
   1284 msgid "SUN4V-8002-G3.response"
   1285 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
   1286 msgid "SUN4V-8002-G3.impact"
   1287 msgstr "System performance may be affected. \n"
   1288 msgid "SUN4V-8002-G3.action"
   1289 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1290 #
   1291 # code: SUN4V-8002-HR
   1292 # keys: fault.cpu.generic-sparc.chip-uc
   1293 #
   1294 msgid "SUN4V-8002-HR.type"
   1295 msgstr "Fault"
   1296 msgid "SUN4V-8002-HR.severity"
   1297 msgstr "Critical"
   1298 msgid "SUN4V-8002-HR.description"
   1299 msgstr "This chip has encountered a chip-level uncorrectable error.\n  Refer to %s for more information."
   1300 msgid "SUN4V-8002-HR.response"
   1301 msgstr "The system will attempt to retire all strands in this chip.\n"
   1302 msgid "SUN4V-8002-HR.impact"
   1303 msgstr "System performance may be affected. \n"
   1304 msgid "SUN4V-8002-HR.action"
   1305 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1306 #
   1307 # code: SUN4V-8002-J4
   1308 # keys: fault.cpu.generic-sparc.chip-uc-nr
   1309 #
   1310 msgid "SUN4V-8002-J4.type"
   1311 msgstr "Fault"
   1312 msgid "SUN4V-8002-J4.severity"
   1313 msgstr "Critical"
   1314 msgid "SUN4V-8002-J4.description"
   1315 msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n  Refer to %s for more information."
   1316 msgid "SUN4V-8002-J4.response"
   1317 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
   1318 msgid "SUN4V-8002-J4.impact"
   1319 msgstr "System performance may be affected. \n"
   1320 msgid "SUN4V-8002-J4.action"
   1321 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1322 #
   1323 # code: SUN4V-8002-KQ
   1324 # keys: fault.cpu.generic-sparc.c2c
   1325 #
   1326 msgid "SUN4V-8002-KQ.type"
   1327 msgstr "Fault"
   1328 msgid "SUN4V-8002-KQ.severity"
   1329 msgstr "Major"
   1330 msgid "SUN4V-8002-KQ.description"
   1331 msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n  Refer to %s for more information."
   1332 msgid "SUN4V-8002-KQ.response"
   1333 msgstr "No automated response.\n"
   1334 msgid "SUN4V-8002-KQ.impact"
   1335 msgstr "System performance may be affected.\n"
   1336 msgid "SUN4V-8002-KQ.action"
   1337 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
   1338 #
   1339 # code: SUN4V-8002-LC
   1340 # keys: fault.cpu.generic-sparc.c2c-failover
   1341 #
   1342 msgid "SUN4V-8002-LC.type"
   1343 msgstr "Fault"
   1344 msgid "SUN4V-8002-LC.severity"
   1345 msgstr "Major"
   1346 msgid "SUN4V-8002-LC.description"
   1347 msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n  Refer to %s for more information."
   1348 msgid "SUN4V-8002-LC.response"
   1349 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
   1350 msgid "SUN4V-8002-LC.impact"
   1351 msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n"
   1352 msgid "SUN4V-8002-LC.action"
   1353 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
   1354 #
   1355 # code: SUN4V-8002-MJ
   1356 # keys: fault.cpu.generic-sparc.c2c-uc
   1357 #
   1358 msgid "SUN4V-8002-MJ.type"
   1359 msgstr "Fault"
   1360 msgid "SUN4V-8002-MJ.severity"
   1361 msgstr "Critical"
   1362 msgid "SUN4V-8002-MJ.description"
   1363 msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n  Refer to %s for more information."
   1364 msgid "SUN4V-8002-MJ.response"
   1365 msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n"
   1366 msgid "SUN4V-8002-MJ.impact"
   1367 msgstr "The system halts and must be restarted.  The integrity of this system has\nbeen compromised.\n"
   1368 msgid "SUN4V-8002-MJ.action"
   1369 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
   1370 #
   1371 # code: SUN4V-8002-NE
   1372 # keys: fault.memory.memlink
   1373 #
   1374 msgid "SUN4V-8002-NE.type"
   1375 msgstr "Fault"
   1376 msgid "SUN4V-8002-NE.severity"
   1377 msgstr "Major"
   1378 msgid "SUN4V-8002-NE.description"
   1379 msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller.  No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n  Refer to %s for more information."
   1380 msgid "SUN4V-8002-NE.response"
   1381 msgstr "The system has recovered from the CRC errors.\n"
   1382 msgid "SUN4V-8002-NE.impact"
   1383 msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n"
   1384 msgid "SUN4V-8002-NE.action"
   1385 msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
   1386 #
   1387 # code: SUN4V-8002-PX
   1388 # keys: fault.memory.memlink-failover
   1389 #
   1390 msgid "SUN4V-8002-PX.type"
   1391 msgstr "Fault"
   1392 msgid "SUN4V-8002-PX.severity"
   1393 msgstr "Major"
   1394 msgid "SUN4V-8002-PX.description"
   1395 msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller.  While no data has been lost, a lane failover\nhas taken place.\n  Refer to %s for more information."
   1396 msgid "SUN4V-8002-PX.response"
   1397 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
   1398 msgid "SUN4V-8002-PX.impact"
   1399 msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n"
   1400 msgid "SUN4V-8002-PX.action"
   1401 msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n"
   1402 #
   1403 # code: SUN4V-8002-Q2
   1404 # keys: fault.memory.memlink-uc
   1405 #
   1406 msgid "SUN4V-8002-Q2.type"
   1407 msgstr "Fault"
   1408 msgid "SUN4V-8002-Q2.severity"
   1409 msgstr "Critical"
   1410 msgid "SUN4V-8002-Q2.description"
   1411 msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n  Refer to %s for more information."
   1412 msgid "SUN4V-8002-Q2.response"
   1413 msgstr "The system crashed to prevent data corruption.  Memory in the affected\npartition may have been deconfigured.  (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n"
   1414 msgid "SUN4V-8002-Q2.impact"
   1415 msgstr "If memory has been deconfigured, system performance may be impacted. \n"
   1416 msgid "SUN4V-8002-Q2.action"
   1417 msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n"
   1418 #
   1419 # code: SUN4V-8002-RA
   1420 # keys: defect.fw.generic-sparc.addr-oob
   1421 #
   1422 msgid "SUN4V-8002-RA.type"
   1423 msgstr "Fault"
   1424 msgid "SUN4V-8002-RA.severity"
   1425 msgstr "Critical"
   1426 msgid "SUN4V-8002-RA.description"
   1427 msgstr "An address-out-of-bounds error has occurred.\n  Refer to %s for more information."
   1428 msgid "SUN4V-8002-RA.response"
   1429 msgstr "No automated response.\n"
   1430 msgid "SUN4V-8002-RA.impact"
   1431 msgstr "The system may have taken a fatal reset.\n"
   1432 msgid "SUN4V-8002-RA.action"
   1433 msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n"
   1434 #
   1435 # code: SUN4V-8002-SP
   1436 # keys: defect.fw.generic-sparc.erpt-gen
   1437 #
   1438 msgid "SUN4V-8002-SP.type"
   1439 msgstr "Fault"
   1440 msgid "SUN4V-8002-SP.severity"
   1441 msgstr "Major"
   1442 msgid "SUN4V-8002-SP.description"
   1443 msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n  Refer to %s for more information."
   1444 msgid "SUN4V-8002-SP.response"
   1445 msgstr "No automated response.\n"
   1446 msgid "SUN4V-8002-SP.impact"
   1447 msgstr "This error does not affect system operation.  The error which\ncould not be reported may have more serious impact which cannot be determined.\n"
   1448 msgid "SUN4V-8002-SP.action"
   1449 msgstr "Call your service provider to determine if your system requires a firmware\nupgrade.  Please retain the error log file.\n"
   1450 #
   1451 # code: SUN4V-8002-T5
   1452 # keys: fault.cpu.generic-sparc.bootbus
   1453 #
   1454 msgid "SUN4V-8002-T5.type"
   1455 msgstr "Fault"
   1456 msgid "SUN4V-8002-T5.severity"
   1457 msgstr "Critical"
   1458 msgid "SUN4V-8002-T5.description"
   1459 msgstr "A system boot bus error has occurred.\n  Refer to %s for more information."
   1460 msgid "SUN4V-8002-T5.response"
   1461 msgstr "No automated response.\n"
   1462 msgid "SUN4V-8002-T5.impact"
   1463 msgstr "The system's integrity is seriously compromised.  Processor chip(s)\nmay be unavailable.\n"
   1464 msgid "SUN4V-8002-T5.action"
   1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
   1466 #
   1467 # code: SUN4V-8002-US
   1468 # keys: fault.sp.failed
   1469 #
   1470 msgid "SUN4V-8002-US.type"
   1471 msgstr "Fault"
   1472 msgid "SUN4V-8002-US.severity"
   1473 msgstr "Critical"
   1474 msgid "SUN4V-8002-US.description"
   1475 msgstr "The Service Processor failed.\n  Refer to %s for more information."
   1476 msgid "SUN4V-8002-US.response"
   1477 msgstr "No automated response.\n"
   1478 msgid "SUN4V-8002-US.impact"
   1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
   1480 msgid "SUN4V-8002-US.action"
   1481 msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"
   1482