1 # 2 # Copyright 2010 Sun Microsystems, Inc. All rights reserved. 3 # Use is subject to license terms. 4 # 5 # CDDL HEADER START 6 # 7 # The contents of this file are subject to the terms of the 8 # Common Development and Distribution License (the "License"). 9 # You may not use this file except in compliance with the License. 10 # 11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12 # or http://www.opensolaris.org/os/licensing. 13 # See the License for the specific language governing permissions 14 # and limitations under the License. 15 # 16 # When distributing Covered Code, include this CDDL HEADER in each 17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18 # If applicable, add the following below this CDDL HEADER, with the 19 # fields enclosed by brackets "[]" replaced with your own identifying 20 # information: Portions Copyright [yyyy] [name of copyright owner] 21 # 22 # CDDL HEADER END 23 # 24 # DO NOT EDIT -- this file is generated by the Event Registry. 25 # 26 # 27 # General-purpose messages 28 # 29 msgid "syslog-msgs-message-template" 30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" 31 msgid "syslog-msgs-pointer" 32 msgstr "\n...\nSee fmadm faulty -u <EVENT-ID> for full information.\n" 33 34 # 35 # Fault-related messages 36 # 37 # 38 # 39 # code: FMD-8000-0W 40 # keys: defect.sunos.fmd.nosub 41 # 42 msgid "FMD-8000-0W.type" 43 msgstr "Defect" 44 msgid "FMD-8000-0W.severity" 45 msgstr "Minor" 46 msgid "FMD-8000-0W.description" 47 msgstr "The Solaris Fault Manager received an event %<fault-list[0].nosub_class> to which no automated diagnosis software is currently subscribed. Refer to %s for more information." 48 msgid "FMD-8000-0W.response" 49 msgstr "Error reports from the component will be logged for examination by Sun." 50 msgid "FMD-8000-0W.impact" 51 msgstr "Automated diagnosis and response for these events will not occur." 52 msgid "FMD-8000-0W.action" 53 msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." 54 # 55 # code: FMD-8000-11 56 # keys: defect.sunos.fmd.nodiagcode 57 # 58 msgid "FMD-8000-11.type" 59 msgstr "Defect" 60 msgid "FMD-8000-11.severity" 61 msgstr "Minor" 62 msgid "FMD-8000-11.description" 63 msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." 64 msgid "FMD-8000-11.response" 65 msgstr "The diagnosis has been saved in the fault log for examination by Sun." 66 msgid "FMD-8000-11.impact" 67 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 68 msgid "FMD-8000-11.action" 69 msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." 70 # 71 # code: FMD-8000-2K 72 # keys: defect.sunos.fmd.module 73 # 74 msgid "FMD-8000-2K.type" 75 msgstr "Defect" 76 msgid "FMD-8000-2K.severity" 77 msgstr "Minor" 78 msgid "FMD-8000-2K.description" 79 msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." 80 msgid "FMD-8000-2K.response" 81 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 82 msgid "FMD-8000-2K.impact" 83 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 84 msgid "FMD-8000-2K.action" 85 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." 86 # 87 # code: FMD-8000-3F 88 # keys: defect.sunos.fmd.config 89 # 90 msgid "FMD-8000-3F.type" 91 msgstr "Defect" 92 msgid "FMD-8000-3F.severity" 93 msgstr "Minor" 94 msgid "FMD-8000-3F.description" 95 msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." 96 msgid "FMD-8000-3F.response" 97 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." 98 msgid "FMD-8000-3F.impact" 99 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." 100 msgid "FMD-8000-3F.action" 101 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." 102 # 103 # code: FMD-8000-4M 104 # keys: list.repaired 105 # 106 msgid "FMD-8000-4M.type" 107 msgstr "Repair" 108 msgid "FMD-8000-4M.severity" 109 msgstr "Minor" 110 msgid "FMD-8000-4M.description" 111 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 112 msgid "FMD-8000-4M.response" 113 msgstr "Some system components offlined because of the original fault may have been brought back online.\n" 114 msgid "FMD-8000-4M.impact" 115 msgstr "Performance degradation of the system due to the original fault may have been recovered.\n" 116 msgid "FMD-8000-4M.action" 117 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." 118 # 119 # code: FMD-8000-58 120 # keys: list.updated 121 # 122 msgid "FMD-8000-58.type" 123 msgstr "Update" 124 msgid "FMD-8000-58.severity" 125 msgstr "Minor" 126 msgid "FMD-8000-58.description" 127 msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information." 128 msgid "FMD-8000-58.response" 129 msgstr "Some system components offlined because of the original fault may have been brought back online.\n" 130 msgid "FMD-8000-58.impact" 131 msgstr "Performance degradation of the system due to the original fault may have been recovered.\n" 132 msgid "FMD-8000-58.action" 133 msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired.\n" 134 # 135 # code: FMD-8000-6U 136 # keys: list.resolved 137 # 138 msgid "FMD-8000-6U.type" 139 msgstr "Resolved" 140 msgid "FMD-8000-6U.severity" 141 msgstr "Minor" 142 msgid "FMD-8000-6U.description" 143 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." 144 msgid "FMD-8000-6U.response" 145 msgstr "All system components offlined because of the original fault have been brought back online.\n" 146 msgid "FMD-8000-6U.impact" 147 msgstr "Performance degradation of the system due to the original fault has been recovered.\n" 148 msgid "FMD-8000-6U.action" 149 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components.\n" 150