Home | History | Annotate | Download | only in dicts
      1 #
      2 # Copyright 2010 Sun Microsystems, Inc.  All rights reserved.
      3 # Use is subject to license terms.
      4 #
      5 # CDDL HEADER START
      6 #
      7 # The contents of this file are subject to the terms of the
      8 # Common Development and Distribution License (the "License").
      9 # You may not use this file except in compliance with the License.
     10 #
     11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
     12 # or http://www.opensolaris.org/os/licensing.
     13 # See the License for the specific language governing permissions
     14 # and limitations under the License.
     15 #
     16 # When distributing Covered Code, include this CDDL HEADER in each
     17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
     18 # If applicable, add the following below this CDDL HEADER, with the
     19 # fields enclosed by brackets "[]" replaced with your own identifying
     20 # information: Portions Copyright [yyyy] [name of copyright owner]
     21 #
     22 # CDDL HEADER END
     23 #
     24 # DO NOT EDIT -- this file is generated by the Event Registry.
     25 #
     26 #
     27 # General-purpose messages
     28 #
     29 msgid "syslog-msgs-message-template"
     30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
     31 msgid "syslog-msgs-pointer"
     32 msgstr "\n...\nSee fmadm faulty -u <EVENT-ID> for full information.\n"
     33 
     34 #
     35 # Fault-related messages
     36 #
     37 #
     38 #
     39 # code: FMD-8000-0W
     40 # keys: defect.sunos.fmd.nosub
     41 #
     42 msgid "FMD-8000-0W.type"
     43 msgstr "Defect"
     44 msgid "FMD-8000-0W.severity"
     45 msgstr "Minor"
     46 msgid "FMD-8000-0W.description"
     47 msgstr "The Solaris Fault Manager received an event %<fault-list[0].nosub_class> to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
     48 msgid "FMD-8000-0W.response"
     49 msgstr "Error reports from the component will be logged for examination by Sun."
     50 msgid "FMD-8000-0W.impact"
     51 msgstr "Automated diagnosis and response for these events will not occur."
     52 msgid "FMD-8000-0W.action"
     53 msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly.  Contact Sun for support."
     54 #
     55 # code: FMD-8000-11
     56 # keys: defect.sunos.fmd.nodiagcode
     57 #
     58 msgid "FMD-8000-11.type"
     59 msgstr "Defect"
     60 msgid "FMD-8000-11.severity"
     61 msgstr "Minor"
     62 msgid "FMD-8000-11.description"
     63 msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
     64 msgid "FMD-8000-11.response"
     65 msgstr "The diagnosis has been saved in the fault log for examination by Sun."
     66 msgid "FMD-8000-11.impact"
     67 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
     68 msgid "FMD-8000-11.action"
     69 msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
     70 #
     71 # code: FMD-8000-2K
     72 # keys: defect.sunos.fmd.module
     73 #
     74 msgid "FMD-8000-2K.type"
     75 msgstr "Defect"
     76 msgid "FMD-8000-2K.severity"
     77 msgstr "Minor"
     78 msgid "FMD-8000-2K.description"
     79 msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
     80 msgid "FMD-8000-2K.response"
     81 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
     82 msgid "FMD-8000-2K.impact"
     83 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
     84 msgid "FMD-8000-2K.action"
     85 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
     86 #
     87 # code: FMD-8000-3F
     88 # keys: defect.sunos.fmd.config
     89 #
     90 msgid "FMD-8000-3F.type"
     91 msgstr "Defect"
     92 msgid "FMD-8000-3F.severity"
     93 msgstr "Minor"
     94 msgid "FMD-8000-3F.description"
     95 msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
     96 msgid "FMD-8000-3F.response"
     97 msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
     98 msgid "FMD-8000-3F.impact"
     99 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
    100 msgid "FMD-8000-3F.action"
    101 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
    102 #
    103 # code: FMD-8000-4M
    104 # keys: list.repaired
    105 #
    106 msgid "FMD-8000-4M.type"
    107 msgstr "Repair"
    108 msgid "FMD-8000-4M.severity"
    109 msgstr "Minor"
    110 msgid "FMD-8000-4M.description"
    111 msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
    112 msgid "FMD-8000-4M.response"
    113 msgstr "Some system components offlined because of the original fault may have been brought back online.\n"
    114 msgid "FMD-8000-4M.impact"
    115 msgstr "Performance degradation of the system due to the original fault may have been recovered.\n"
    116 msgid "FMD-8000-4M.action"
    117 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
    118 #
    119 # code: FMD-8000-58
    120 # keys: list.updated
    121 #
    122 msgid "FMD-8000-58.type"
    123 msgstr "Update"
    124 msgid "FMD-8000-58.severity"
    125 msgstr "Minor"
    126 msgid "FMD-8000-58.description"
    127 msgstr "Some faults associated with an event id have been addressed.\n  Refer to %s for more information."
    128 msgid "FMD-8000-58.response"
    129 msgstr "Some system components offlined because of the original fault may have been brought back online.\n"
    130 msgid "FMD-8000-58.impact"
    131 msgstr "Performance degradation of the system due to the original fault may have been recovered.\n"
    132 msgid "FMD-8000-58.action"
    133 msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired.\n"
    134 #
    135 # code: FMD-8000-6U
    136 # keys: list.resolved
    137 #
    138 msgid "FMD-8000-6U.type"
    139 msgstr "Resolved"
    140 msgid "FMD-8000-6U.severity"
    141 msgstr "Minor"
    142 msgid "FMD-8000-6U.description"
    143 msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
    144 msgid "FMD-8000-6U.response"
    145 msgstr "All system components offlined because of the original fault have been brought back online.\n"
    146 msgid "FMD-8000-6U.impact"
    147 msgstr "Performance degradation of the system due to the original fault has been recovered.\n"
    148 msgid "FMD-8000-6U.action"
    149 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components.\n"
    150